Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Human LPL ELISA Kit PicoKine®

Human LPL PicoKine® ELISA Kit (96 Tests) . Quantitate Human LPL in cell culture supernatants, serum and plasma (heparin, EDTA) . Sensitivity: 40 pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Specifications

Background

LPL encodes lipoprotein lipase, which is expressed in heart, muscle, and adipose tissue. LPL functions as a homodimer, and has the dual functions of triglyceride hydrolase and ligand/bridging factor for receptor-mediated lipoprotein uptake. Severe mutations that cause LPL deficiency result in type I hyperlipoproteinemia, while less extreme mutations in LPL are linked to many disorders of lipoprotein metabolism.

Reproducibility

Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 137 100 85 132 114 3.71 3.3% Sample 2 201 296 166 236 225 4.72 2.1% Sample 3 2403 2329 2427 2205 2341 163.17 7% Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Lots Lot 1 (pg/ml) Lot 2 (pg/ml) Lot 3 (pg/ml) Lot 4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%) Sample 1 137 100 85 132 114 3.71 3.3% Sample 1 137 100 85 132 114 3.71 3.3% Sample 2 201 296 166 236 225 4.72 2.1% Sample 2 201 296 166 236 225 4.72 2.1% Sample 3 2403 2329 2427 2205 2341 163.17 7% Sample 3 2403 2329 2427 2205 2341 163.17 7%

Gene Name

LPL

Gene ID

4023

UniProt

P06858

Reactivity

Human

Cross Reactivity

There is no detectable cross-reactivity with other relevant proteins.

Immunogen

Expression system for standard: CHO; Immunogen sequence: A28-G475

Capture Antibody

A polyclonal antibody from goat

Detection Antibody

A biotinylated polyclonal antibody from goat

Applications

ELISA

Standard

10 ng/Tube

Sample Type

Cell culture supernatants, serum and plasma (heparin, EDTA)

Detection Range

78 pg/mL - 5,000 pg/mL

Precision

Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 137 201 2403 127 163 2010 Standard deviation 9.55 9.27 160.76 5.82 11.8 98.49 CV (%) 7% 4.6% 6.7% 4.6% 7.2% 4.9% Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 Mean (pg/ml) 137 201 2403 127 163 2010 Standard deviation 9.55 9.27 160.76 5.82 11.8 98.49 CV (%) 7% 4.6% 6.7% 4.6% 7.2% 4.9% Intra-Assay Precision Inter-Assay Precision Intra-Assay Precision Inter-Assay Precision Sample 1 2 3 1 2 3 Sample 1 2 3 1 2 3 n 16 16 16 24 24 24 n 16 16 16 24 24 24 Mean (pg/ml) 137 201 2403 127 163 2010 Mean (pg/ml) 137 201 2403 127 163 2010 Standard deviation 9.55 9.27 160.76 5.82 11.8 98.49 Standard deviation 9.55 9.27 160.76 5.82 11.8 98.49 CV (%) 7% 4.6% 6.7% 4.6% 7.2% 4.9% CV (%) 7% 4.6% 6.7% 4.6% 7.2% 4.9%

Sensitivity

<40 pg/mL

Components

Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x) |100ul Avidin-Biotin-Peroxidase Complex (100x) |100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB) |10ml Stop Solution|10ml Wash Buffer (25x) |20ml Adhesive plate sealers|4

Storage Conditions

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Specificity

Natural and recombinant human LPL

Anticoagulant

Heparin or EDTA

Sample Data

Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.073 0.167 0.225 0.369 0.6259 1.107 1.793 2.4 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.073 0.167 0.225 0.369 0.6259 1.107 1.793 2.4 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 Concentration (pg/ml) 0 78 156 312 625 1250 2500 5000 O.D. 0.073 0.167 0.225 0.369 0.6259 1.107 1.793 2.4 O.D. 0.073 0.167 0.225 0.369 0.6259 1.107 1.793 2.4

Material Required But Not Provided

Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer (optional) . Pipettes and pipette tips capable of precisely dispensing 0.5 μl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Fibrinogen gamma Chain Antibody
OC-132-01 50 μL

Fibrinogen gamma Chain Antibody

Sign In for Pricing
View Details
Fibrinogen gamma Chain Antibody
OC-132-02 100 µL

Fibrinogen gamma Chain Antibody

Sign In for Pricing
View Details
Fibrinogen gamma Chain Antibody
OC-132-03 1 mL

Fibrinogen gamma Chain Antibody

Sign In for Pricing
View Details
BAX Monoclonal Antibody
E-AB-22128-01 20 µL

BAX Monoclonal Antibody

Sign In for Pricing
View Details
BAX Monoclonal Antibody
E-AB-22128-02 60 µL

BAX Monoclonal Antibody

Sign In for Pricing
View Details
BAX Monoclonal Antibody
E-AB-22128-03 120 µL

BAX Monoclonal Antibody

Sign In for Pricing
View Details