Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Klotho (KL)

Product Specifications

Product Name Alternative

KLa; Klotho Alpha

UniProt

Q9UEF7

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Metabolic pathway

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Klotho (KL) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Klotho (KL) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Klotho (KL) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Detection Range

41.2-30,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Klotho (KL) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Klotho (KL) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 16.8pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Klotho (KL) . No significant cross-reactivity or interference between Klotho (KL) and analogues was observed.

Product Name Synonym

Klotho

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Biotinylated Anti-IL18 (aletekitug biosimilar) mAb
12-90052B-50 50 µg

Biotinylated Anti-IL18 (aletekitug biosimilar) mAb

Sign In for Pricing
View Details
FUT2 Rabbit Polyclonal Antibody (Cy5.5)
orb1057047 100 µL

FUT2 Rabbit Polyclonal Antibody (Cy5.5)

Sign In for Pricing
View Details
GRIN2A Antibody
55-788 400 µL

GRIN2A Antibody

Sign In for Pricing
View Details
SNX19P2 Lentiviral Vector (Human) (CMV) (pLenti-GIII-CMV-RFP-2A-Puro)
LV786200 1.0 µg DNA

SNX19P2 Lentiviral Vector (Human) (CMV) (pLenti-GIII-CMV-RFP-2A-Puro)

Sign In for Pricing
View Details
Bz 423 50 mg
5791/50 50 mg

Bz 423 50 mg

Sign In for Pricing
View Details
LRTM2 Recombinant Protein Antigen
NBP3-17514PEP 100 µL

LRTM2 Recombinant Protein Antigen

Sign In for Pricing
View Details