Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Human AhR (Aryl Hydrocarbon Receptor) ELISA Kit

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AhR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AhR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AhR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AhR in the samples is then determined by comparing the OD of the samples to the standard curve.

Product Specifications

Product Name Alternative

BHLHE76; Class E basic helix-loop-helix protein 76

UniProt

P35869

Reactivity

Human

Field of Research

Signal transduction; Tumor immunity; Infection immunity; Dermatology

Assay Type

Sandwich

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AhR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AhR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AhR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AhR in the samples is then determined by comparing the OD of the samples to the standard curve.

Assay Performance Time

3.5h

Standard

5000 pg/mL

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Detection Range

78.13-5000 pg/mL

Sensitivity

27 pg/mL

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Pmel17 / gp100 / SILV (NKI-beteb), CF740 conjugate, 0.1mg/mL
BNC740226-500 1x 500 µL

Pmel17 / gp100 / SILV (NKI-beteb), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Complement C4d (C4D204), CF405S conjugate, 0.1mg/mL
BNC040204-100 1x 100 µL

Complement C4d (C4D204), CF405S conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD50 / ICAM3 (CG106), CF740 conjugate, 0.1mg/mL
BNC742216-500 1x 500 µL

CD50 / ICAM3 (CG106), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD28 (204.12), CF594 conjugate, 0.1mg/mL
BNC940164-500 1x 500 µL

CD28 (204.12), CF594 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD11c (HC1/1), CF740 conjugate, 0.1mg/mL
BNC740152-100 1x 100 µL

CD11c (HC1/1), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD16 (C16/1045), CF568 conjugate, 0.1mg/mL
BNC681045-500 1x 500 µL

CD16 (C16/1045), CF568 conjugate, 0.1mg/mL

Sign In for Pricing
View Details