Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Human CLIC1 (Chloride Intracellular Channel Protein 1) ELISA Kit

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CLIC1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CLIC1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CLIC1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CLIC1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Product Specifications

Product Name Alternative

G6; NCC27; p64CLCP; hRNCC; Chloride channel ABP; Nuclear chloride ion channel 27; Regulatory nuclear chloride ion channel protein

UniProt

O00299

Reactivity

Human

Field of Research

Signal transduction; Metabolic pathway

Assay Type

Sandwich

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CLIC1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CLIC1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CLIC1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CLIC1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Assay Performance Time

3.5h

Standard

20 ng/mL

Sample Type

Tissue homogenates, cell lysates and other biological fluids.

Detection Range

0.32-20 ng/mL

Sensitivity

0.117 ng/mL

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

CD5 (Cris-1), CF740 conjugate, 0.1mg/mL
BNC740176-100 1x 100 µL

CD5 (Cris-1), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
MUC2 (CCP58), CF488A conjugate, 0.1mg/mL
BNC880032-500 1x 500 µL

MUC2 (CCP58), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
FOXP3 (3G3), CF488A conjugate, 0.1mg/mL
BNC880645-500 1x 500 µL

FOXP3 (3G3), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Bax (2D2), CF594 conjugate, 0.1mg/mL
BNC940004-100 1x 100 µL

Bax (2D2), CF594 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
P21 / WAF1 (DCS-60.2), CF740 conjugate, 0.1mg/mL
BNC740822-100 1x 100 µL

P21 / WAF1 (DCS-60.2), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD56 / NCAM1 / NKH1 (Neuronal Cell Marker) (NCAM1/2217R), CF647 conjugate, 0.1mg/mL
BNC472217-100 1x 100 µL

CD56 / NCAM1 / NKH1 (Neuronal Cell Marker) (NCAM1/2217R), CF647 conjugate, 0.1mg/mL

Sign In for Pricing
View Details