Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Omalizumab (Xolair) Pharmacokinetic ELISA

Omalizumab (Xolair®) is a recombinant DNA-derived humanized IgG1κ monoclonal antibody that binds human immunoglobulin E (IgE) for the treatment of moderate to severe persistent allergic asthma and Chronic Idiopathic Urticaria (CIU) . Omalizumab inhibits the binding of IgE to IgE receptor (FcεRI) on the surface of mast cells and basophils thereby limiting the release of mediators of the allergic response from the FcεRI bearing cells.

Product Specifications

CAS Number

7732-18-5

Gene ID

3497

Reactivity

Human, mouse, rat

Reaction Volume

15 µL

Target Antigen

Omalizumab (Xolair)

Detection Method

Peroxidase / OD450

Assay Type

ELISA

Assay Principle

Quantification of Omalizumab in biological matrices

Assay Protocol

The Omalizumab ELISA kit is designed to measure free Omalizumab with high specificity and sensitivity . This assay employs the sandwich enzyme immunoassay technique. A precoated anti-Omalizumab 96 well plate is provided. Calibrator, quality control samples and test samples are pipetted into the appropriate wells. Omalizumab present in biological matrices is bound by the immobilized capture antibody. After washing away any unbound substances, enzyme linked detection antibody is added to the wells. The plate is washed to remove any unbound antibody-enzyme reagent and a substrate solution is added to the wells for color development. The color development is proportional to the amount of Omalizumab present in test samples and the concentration is calculated from the standard series.

Assay Performance Time

2.5 hours

Sample Type

Serum Plasma

Sample Volume

15ul

Detection Range

50ng/ml - 1.56ng/ml

Precision

<10%, <10%

Sensitivity

Omalizumab

Limit Of Detection

1.5ng/ml

Components

Coated microtiter plate, 96 wells Calibrator diluent. - 1.8ml Calibrator 12ul 10X wash buffer - 25ml Assay buffer - 50ml 1000X detection reagent - 17ul TMB - 12ml TMB stop solution - 12ml Plate sealers - 3

Shipping Conditions

Blue Ice

Storage Conditions

-20C, 1 year

Shelf Life

12 months

Specificity

Omalizumab

Method

Direct sandwich ELISA

Preservative

None

Preparation

Prepare only the appropriate amount of required reagent on the day of use. Store all reagents as per instructions stated on the label. 1. Wash Buffer (1X) Preparation: Dilute wash buffer concentrate with ultra-pure water 1/10 before use (for example add 20mL concentrate to 180mL ultra-pure water) . Mix well. 2. Detection Reagent (1X) Preparation: Dilute detection reagent with assay buffer 1/1000 before use (for example add 11μl concentrate to 11ml of assay buffer) . Mix well. 3. Preparation of Calibrators: Prepare calibrators with concentrations ranging from 2,500 ng/mL to 78 ng/mL. The following is an example calibrator curve.

Operating Procedure

This assay employs the sandwich enzyme immunoassay technique. Anti- Omalizumab is coated onto a 96 well microplate. Calibrator and test samples are pipetted into the appropriate wells. Omalizumab present in biological matrices is bound by the immobilized anti- Omalizumab antibody. After washing away any unbound substances, enzyme linked anti- Omalizumab antibody is added to the wells. This antibody is developed and purified specifically against Xolair® (domain residing in Fc portion of the Xolair® molecule) . The plate is washed to remove any unbound antibody-enzyme reagent and a substrate solution is added to the wells for color development. The color development is proportional to the amount of Omalizumab present in test samples. The color development is stopped and the intensity of the color is measured

Results Calculation

1. Construct a standard curve by plotting the absorbance obtained from each standard against concentration. Use a 4 or 5 parameter curve fit. Alternatively a log-log curve fit may be used. 2. The concentration of the unknowns can be read directly from this standard curve using the absorbance value for each sample. 3. Any sample undiluted or diluted still reading greater than the highest standard should be diluted appropriately with calibrator diluent and retested. If the samples have been diluted, the concentration determined from the standard curve must be multiplied by the dilution factor

Sample Collection

This kit is compatible with EDTA-plasma, heparinplasma and serum samples. Samples can be stored at or below -20°C for up to 1 year.

Sample Preparation

Dilute calibrators and test samples 1/50 with assay buffer (for example add 5µL of prepared calibrator or sample to 245µL of assay buffer) . Mix well. Do not store diluted samples.

Plate

Strip

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Rabbit Polyclonal FLYWCH2 Antibody
NBP3-05083-100ul 100 µL

Rabbit Polyclonal FLYWCH2 Antibody

Ask
View Details
Rabbit Polyclonal FPRL1/FPR2 Antibody [Alexa Fluor 700]
NLS1878AF700 0.05 mL

Rabbit Polyclonal FPRL1/FPR2 Antibody [Alexa Fluor 700]

Ask
View Details
Rabbit Monoclonal TXNDC12 Antibody (SR1258)
NBP3-22499-50ul 50 µL

Rabbit Monoclonal TXNDC12 Antibody (SR1258)

Ask
View Details