Human Signal transducer and activator of transcription 1 (STAT1) ELISA Kit
This Human Signal transducer and activator of transcription 1 (STAT1) ELISA Kit employs a two-site sandwich ELISA to quantitate STAT1.
Product Specifications
Background
STAT1 is a member of the Signal Transducers and Activators of Transcription family of transcription factors. STAT1 is involved in upregulating genes due to a signal by either type I or type II interferons. In response to IFN-gamma; stimulation, STAT1 forms homodimers or heterodimers with STAT3 that bind to the GAS (Interferon-Gamma Activated Sequence) promoter element; in response to either IFN-α or IFN-β stimulation, STAT1 forms a heterodimer with STAT2 that can bind the ISRE (Interferon Stimulated Response Element) promoter element. In either case, binding of the promoter element leads to an increased expression of ISG (Interferon Stimulated Genes) .Expression of STAT1 can be induced with diallyl disulfide, a compound in garlic.
CAS Number
7732-18-5
Product Name Alternative
STAT1; DKFZp686B04100; ISGF-3; STAT91; OTTHUMP00000205845; signal transducer and activator of transcription 1; signal transducer and activator of transcription-1; transcription factor ISGF-3 components p91/p8
Gene ID
6772
Accession Number
P42224
Reactivity
Human
Tag
STAT1
Type
Cell analysis
Applications
ELISA
Detection Method
Colorimetric
Assay Type
Sandwich ELISA (quantitative)
Assay Performance Time
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Sample Type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Limit Of Detection
Please inquire
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Features & Benefits
Human Signal transducer and activator of transcription 1 (STAT1) ELISA Kit has high sensitivity and excellent specificity for detection of Human STAT1. No significant cross-reactivity or interference between Human STAT1 and analogues was observed.
Shipping Conditions
Gel pack with blue ice.
Storage Conditions
The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.
Applications Notes
This Human Signal transducer and activator of transcription 1 (STAT1) ELISA Kit employs a two-site sandwich ELISA to quantitate STAT1 in samples. An antibody specific for STAT1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anySTAT1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for STAT1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of STAT1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Other Product Names
STAT1; DKFZp686B04100; ISGF-3; STAT91; OTTHUMP00000205845; signal transducer and activator of transcription 1; signal transducer and activator of transcription-1; transcription factor ISGF-3 components p91/p8
Tested Applications
ELISA Testing
Recommended Usage
• Do not mix components from different kit lots or use reagents beyond the kit expiration date.• Allow all reagents to warm to room temperature for at least 30 minutes before opening.• Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.• Unused wells must be kept desiccated at 4 °C in the sealed bag provided.• Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.• It is recommended that all samples and standards be assayed in duplicate or triplicate.
Accession Number URL
http://www.uniprot.org/uniprot/P42224
Calibration Range
Please inquire
Available Sizes
Frequently Asked Questions
More Discoveries
Explore Other Products
Browse additional items from our catalog