Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Student Oscilloscope

DEFLECTION COEFFICIENT SCOPE OF COLLECTOR 20μA/DIV, DIVIDED INTO 15 CURRENT (1C) GRADES, ERROR IS NOT MORE THAN ± 3% 0.2μ A/DIV~1A/DIV, DIVIDED INTO 6 GRADES 2μ A/DIV~10μ A/DIV, ERROR IS NOT MORE THAN ± 3% REVERSAL DRAIN CURRENT OF 0.2μ A/DIV~1A/DIV, ERROR IS DIODE (1R) NOT MORE THAN ± 10% 0.2μ A/DIV, INTERFERE = 0.5V/DIV BASE CURRENT OR BASE VOLTAGE 20MV/DIV, ERROR= ±3%, DEFLECTION MULTIFYING FACTOR X0.5, ERROR = ±10% DEFLECTION COEFFICIENT SCOPE OF COLLECTOR VOLTAGE 0.05V/DIV~500V/DIV DIVIDED INTO 10 GRADES, ERROR OF HORIZONTAL AXIS < ± 3% SCOPE OF DRAIN CURRENT 100V/DIV~500V/DIV DIVIDED VOLTAGE OF DIODE INTO 3 GRADES, ERROR < ±5% (FOR MATCHING 5KV TEST FLOOR) SCOPE OF BASE VOLTAGE 0.05V/DIV~2V/DIV, DIVIDED INTO 6 GRADES, ERROR <_ ± 3% BASE CURRENT OF BASE SOURCE VOLTAGE 0.1V/DIV, ERROR = ± 3% STEP SIGL SCOPE OF STEP CURRENT 1 μA/STAGE~0.1A/STAGE, DIVIDED IN TO 16 GRADES, ERROR = ± 5% SCOPE OF STEP VOLTAGE 0.05V/STAGE~2V/STAGE, DIVIDED INTO 6 GRADES, ERROR = ± 5% STAGE NUMBER PER CLUSTER 4~10 STAGES CONTINUOUSLY ADJUSTABLE STEP ZEROING NOT LESS THAN ± 1DIV STEP NUMBER PER SECOND 200 (COMMERCIAL FREQUENCY :50HZ) STEP POLARITY POSITIVE OR NEGATIVE STEP FORM CONTINUOUS OR SINGLE CLUSTER COLLECTOR SWEEP MAX. CURRENT OF SWEEP 0~5V GRADE:10A SUPPLY EACH GRADE 0~20V GRADE: 2.5A 0~100V GRADE: 0.5A 0~500V GRADE: 0.1A DISSIPATION RESISTANCE 0~500KO, DIVIDED INTO 11 GRADES 10O~500KO, ERROR = ± 10% 0.5O~2.5O, ERROR = ± 20% POWER SOURCE 220VAC±10%, 50HZ±2HZ DIMENSIONS (WXHXD) 240X330X480MM WEIGHT 13.5KG

Product Specifications

Origin

BO

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

CD59 (heavy chain of Protectin) (BRA-10G), CF488A conjugate, 0.1mg/mL
BNC880181-100 1x 100 µL

CD59 (heavy chain of Protectin) (BRA-10G), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD86 (BU63), CF594 conjugate, 0.1mg/mL
BNC940193-100 1x 100 µL

CD86 (BU63), CF594 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD7 (T3-3A1), CF488A conjugate, 0.1mg/mL
BNC880978-500 1x 500 µL

CD7 (T3-3A1), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD11a (Cris-3), CF488A conjugate, 0.1mg/mL
BNC880151-500 1x 500 µL

CD11a (Cris-3), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD44 Standard (DF1485), CF647 conjugate, 0.1mg/mL
BNC471037-100 1x 100 µL

CD44 Standard (DF1485), CF647 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Catenin, gamma (Cardiomyocyte Marker) (rCTNG/1664), CF594 conjugate, 0.1mg/mL
BNC942156-500 1x 500 µL

Catenin, gamma (Cardiomyocyte Marker) (rCTNG/1664), CF594 conjugate, 0.1mg/mL

Sign In for Pricing
View Details