ELISA Kit for Hypoxia Inducible Factor 1 Alpha (HIF1a)
Product Specifications
Product Name Alternative
HIF1-A; MOP1; PASD8; Basic Helix-Loop-Helix Transcription Factor; ARNT-interacting protein; Basic-helix-loop-helix-PAS protein MOP1; Class E basic helix-loop-helix protein 78
UniProt
Q9XTA5
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Field of Research
Tumor immunity; Cardiovascular biology; Reproductive science
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Hypoxia Inducible Factor 1 Alpha (HIF1a) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Hypoxia Inducible Factor 1 Alpha (HIF1a) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Hypoxia Inducible Factor 1 Alpha (HIF1a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Hypoxia Inducible Factor 1 Alpha (HIF1a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Performance Time
3h
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Detection Range
0.156-10ng/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Hypoxia Inducible Factor 1 Alpha (HIF1a) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Hypoxia Inducible Factor 1 Alpha (HIF1a) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 0.055ng/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Hypoxia Inducible Factor 1 Alpha (HIF1a) . No significant cross-reactivity or interference between Hypoxia Inducible Factor 1 Alpha (HIF1a) and analogues was observed.
Product Name Synonym
Hypoxia Inducible Factor 1 Alpha
Method
Double-antibody Sandwich
Organism Species
Bos taurus; Bovine (Cattle)
Available Sizes
Curated Selection