Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

ELISA Kit for Epstein Barr Virus Induced Protein 3 (EBI3)

Product Specifications

Product Name Alternative

IL27B; IL27-B; Interleukin 27B; Epstein-Barr virus-induced gene 3 protein; EBV-induced gene 3 protein

UniProt

Q14213

Applications

Enzyme-linked immunosorbent assay for Antigen Detection.

Field of Research

Infection immunity

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Epstein Barr Virus Induced Protein 3 (EBI3) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Epstein Barr Virus Induced Protein 3 (EBI3) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Epstein Barr Virus Induced Protein 3 (EBI3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Epstein Barr Virus Induced Protein 3 (EBI3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Assay Performance Time

3h

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Detection Range

0.156-10ng/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Epstein Barr Virus Induced Protein 3 (EBI3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Epstein Barr Virus Induced Protein 3 (EBI3) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.055ng/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Epstein Barr Virus Induced Protein 3 (EBI3) . No significant cross-reactivity or interference between Epstein Barr Virus Induced Protein 3 (EBI3) and analogues was observed.

Product Name Synonym

Epstein Barr Virus Induced Protein 3

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

B7-2 (CD86) Mouse Monoclonal Antibody [Clone ID: OTI2H4]
CF813081 100 µg

B7-2 (CD86) Mouse Monoclonal Antibody [Clone ID: OTI2H4]

Ask
View Details
BMP5 (Bone Morphogenetic Protein 5, MGC34244) (MaxLight 405) discontinued
243825-ML405 100 µL

BMP5 (Bone Morphogenetic Protein 5, MGC34244) (MaxLight 405) discontinued

Ask
View Details
Recombinant Norovirus GII VP1/ORF2 Protein, C-His
EVV25601 100 μg

Recombinant Norovirus GII VP1/ORF2 Protein, C-His

Ask
View Details
MMACHC antibody
MBS833944-01 0.1 mL

MMACHC antibody

Ask
View Details
MMACHC antibody
MBS833944-02 5x 0.1 mL

MMACHC antibody

Ask
View Details