ELISA Kit for Amine Oxidase, Copper Containing 3 (AOC3)
Product Specifications
Product Name Alternative
VAP1; HPAO; SSAO; Membrane primary amine oxidase; Vascular Adhesion Protein 1; Semicarbazide-Sensitive Amine Oxidase; Copper-Containing Amine Oxygen Oxidoreductase
UniProt
O70423
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Field of Research
Enzyme & Kinase; Infection immunity; Endocrinology; Bone metabolism; Rheumatology
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Amine Oxidase, Copper Containing 3 (AOC3) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Amine Oxidase, Copper Containing 3 (AOC3) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Amine Oxidase, Copper Containing 3 (AOC3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Amine Oxidase, Copper Containing 3 (AOC3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Performance Time
3h
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Detection Range
1.56-100ng/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Amine Oxidase, Copper Containing 3 (AOC3) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Amine Oxidase, Copper Containing 3 (AOC3) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65ng/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Amine Oxidase, Copper Containing 3 (AOC3) . No significant cross-reactivity or interference between Amine Oxidase, Copper Containing 3 (AOC3) and analogues was observed.
Product Name Synonym
Amine Oxidase, Copper Containing 3
Method
Double-antibody Sandwich
Organism Species
Mus musculus (Mouse)
Available Sizes
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items