Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Human VE-Cadherin (Vascular Endothelial Cadherin) ELISA Kit

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VE-Cadherin. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VE-Cadherin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VE-Cadherin, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VE-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve.

Product Specifications

Product Name Alternative

CD144; 7B4; Cadherin 5 Type 2; VE-Cadherin; Cadherin, Vascular Endothelial; CDH5; Cadherin 5

UniProt

P33151

Reactivity

Human

Field of Research

CD & Adhesion molecule; Tumor immunity; Infection immunity

Assay Type

Sandwich

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VE-Cadherin. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VE-Cadherin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VE-Cadherin, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VE-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve.

Assay Performance Time

3.5h

Standard

200 ng/mL

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

3.13-200 ng/mL

Sensitivity

1.21 ng/mL

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

CD8 (C8/1035), CF740 conjugate, 0.1mg/mL
BNC741035-500 1x 500 µL

CD8 (C8/1035), CF740 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD43 (84-3C1), CF647 conjugate, 0.1mg/mL
BNC470342-500 1x 500 µL

CD43 (84-3C1), CF647 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD3e (B-B12), CF770 conjugate, 0.1mg/mL
BNC701052-500 1x 500 µL

CD3e (B-B12), CF770 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD34 (ICO-115), CF488A conjugate, 0.1mg/mL
BNC880039-500 1x 500 µL

CD34 (ICO-115), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details