Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

EasyStep Human ANXA1 (Annexin A1) ELISA Kit

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ANXA1, and the Human ANXA1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human ANXA1. After TMB substrate solution is added, only those wells that contain Human ANXA1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ANXA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Product Specifications

Product Name Alternative

ANX-A1; ANX1; LPC1; Lipocortin I; Chromobindin-9; Calpactin II; Phospholipase A2 inhibitory protein

UniProt

P04083

Reactivity

Human

Field of Research

Tumor immunity

Assay Type

Sandwich

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ANXA1, and the Human ANXA1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells , then added a HRP-conjugated antibody specific to Human ANXA1. After TMB substrate solution is added, only those wells that contain Human ANXA1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ANXA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

Assay Performance Time

1.5h

Standard

20 ng/mL

Sample Type

Serum, plasma

Detection Range

0.32-20 ng/mL

Sensitivity

16.8 pg/mL

Available Sizes

More Discoveries

Explore Other Products

Browse additional items from our catalog

Human ITGB7 Protein Lysate
MBS8413757-01 0.02 mg

Human ITGB7 Protein Lysate

Sign In for Pricing
View Details
Human ITGB7 Protein Lysate
MBS8413757-02 5x 0.02 mg

Human ITGB7 Protein Lysate

Sign In for Pricing
View Details
Rabbit anti-human carboxypeptidase A6 polyclonal Antibody
MBS710800-01 0.1 mL

Rabbit anti-human carboxypeptidase A6 polyclonal Antibody

Sign In for Pricing
View Details
Rabbit anti-human carboxypeptidase A6 polyclonal Antibody
MBS710800-02 5x 0.1 mL

Rabbit anti-human carboxypeptidase A6 polyclonal Antibody

Sign In for Pricing
View Details
MTNR1A (Melatonin Receptor 1A, MEL-1A-R, Mel1a Receptor, MT1) discontinued
151530 100 µg

MTNR1A (Melatonin Receptor 1A, MEL-1A-R, Mel1a Receptor, MT1) discontinued

Sign In for Pricing
View Details
Mouse Metallothionein 2 (MT2) ELISA Kit
RDR-MT2-Mu-48Tests 48 Tests

Mouse Metallothionein 2 (MT2) ELISA Kit

Sign In for Pricing
View Details