Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Multiplex Assay Kit for Ghrelin (GHRL)

Product Specifications

UniProt

Q9BEF8

Applications

FLIA Kit for Antigen Detection.

Assay Principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

Assay Protocol

1. Preparation of standards, reagents and samples before the experiment; <br/> 2. Add 50μL standard or sample to each well, <br/> &nbsp; &nbsp; &nbsp; &nbsp; add 10μL magnetic beads, and 50μL Detection Reagent A, incubate 90min at 37&deg; C on shaker; <br/> 3. Wash plate on magnetic frame for three times; <br/> 4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37&deg; C on shaker; <br/> 5. Wash plate on magnetic frame for three times; <br/> 6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.<br/>

Assay Performance Time

3H

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

0.977 - 1000 pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100, Intra-Assay: CV<10%, Inter-Assay: CV<12%

Sensitivity

The minimum detectable dose of this kit is typically less than 0.326pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Specificity

This assay has high sensitivity and excellent specificity for detection of the target, etc. by FLIA (Flow Luminescence Immunoassay) .<br/> No significant cross-reactivity or interference between the target, etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Method

Competitive Inhibition

Organism Species

Canis familiaris; Canine (Dog)

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Cblb (NM_001033238) Mouse Recombinant Protein
E45M42322M5 20 µg

Cblb (NM_001033238) Mouse Recombinant Protein

Sign In for Pricing
View Details
TSSK4 Rabbit pAb
E45R27765N-100 100 µL

TSSK4 Rabbit pAb

Sign In for Pricing
View Details
Mouse Monoclonal VEGFR2/KDR/Flk-1 Antibody (89106) [PE/Cy7]
FAB3572PECY7 0.1 mL

Mouse Monoclonal VEGFR2/KDR/Flk-1 Antibody (89106) [PE/Cy7]

Sign In for Pricing
View Details
CD159a/c Polyclonal Antibody
41694-01 50 µL

CD159a/c Polyclonal Antibody

Sign In for Pricing
View Details
CD159a/c Polyclonal Antibody
41694-02 100 µL

CD159a/c Polyclonal Antibody

Sign In for Pricing
View Details
P4HB Antibody
E19-6131 100 µg -100 µL

P4HB Antibody

Sign In for Pricing
View Details