Mini Samples ELISA Kit for Glycated Hemoglobin A1c (HbA1c)
Product Specifications
Product Name Alternative
Glycosylated Hemoglobin; Hemoglobin A1c; Hb1c; HbAIc; HbAIc
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Assay Principle
This assay employs the competitive inhibition enzyme immunoassay technique. An antibody specific to HbA1c has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled HbA1c and unlabeled HbA1c (Standards or samples) with the pre-coated antibody specific to HbA1c. After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of HbA1c in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of HbA1c in the sample.
Assay Protocol
1. Prepare all reagents, samples and standards; <br/> 2. Add 25µ L standard or sample to each well.<br/> And then add 25μL prepared Detection Reagent A immediately.<br/> Shake and mix. Incubate 1 hour at 37° C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 50µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 50µ L Substrate Solution. Incubate 10-20 minutes at 37° C; <br/> 7. Add 25µ L Stop Solution. Read at 450 nm immediately.<br/>
Assay Performance Time
3H
Sample Type
Plasma and erythrocyte lysates
Detection Range
12.35 - 1000 µg/mL
Precision
<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Mini Samples Glycated Hemoglobin A1c (HbA1c) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Mini Samples Glycated Hemoglobin A1c (HbA1c) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>
Sensitivity
The minimum detectable dose of this kit is typically less than 4.94ug/mL
Stability
<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>
Specificity
<p> This assay has high sensitivity and excellent specificity for detection of Mini Samples Glycated Hemoglobin A1c (HbA1c) .<br/> No significant cross-reactivity or interference between Mini Samples Glycated Hemoglobin A1c (HbA1c) and analogues was observed. </p>
Method
Competitive Inhibition
Organism Species
Mus musculus (Mouse)
CAS Number