Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Coagulation Factor VIII (F8)

Product Specifications

Product Name Alternative

FVIII; AHF; HEMA; F8B; F8C; Antihemophilic Globulin; Hemophilia A; Anti-Hemophilic Factor A; FVIII Procoagulant Component; F8 Protein

UniProt

P00741

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Metabolic pathway; Hematology

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Coagulation Factor VIII (F8) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Coagulation Factor VIII (F8) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Coagulation Factor VIII (F8) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Plasma

Detection Range

13.7-10,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Coagulation Factor VIII (F8) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Coagulation Factor VIII (F8) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 4.9pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Coagulation Factor VIII (F8) . No significant cross-reactivity or interference between Coagulation Factor VIII (F8) and analogues was observed.

Product Name Synonym

Coagulation Factor VIII

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Conjugated Linoleic Acid, 90%(Mixture of Isomers)
TRC-C685000-50MG 50 mg

Conjugated Linoleic Acid, 90%(Mixture of Isomers)

Sign In for Pricing
View Details
GPR7 (NPBWR1) (NM_005285) Human Over-expression Lysate
LC401627 20 µg

GPR7 (NPBWR1) (NM_005285) Human Over-expression Lysate

Sign In for Pricing
View Details
DSG2 Antibody
8C15333-AAT 50 µg

DSG2 Antibody

Sign In for Pricing
View Details
1,2-Bis(2,4,6-tribromophenoxy)ethane
TRC-B585425-1G 1 g

1,2-Bis(2,4,6-tribromophenoxy)ethane

Sign In for Pricing
View Details
3-(2-Thienyl)acrylic Acid
TRC-T344370-10G 10 g

3-(2-Thienyl)acrylic Acid

Sign In for Pricing
View Details
Oltipraz
TRC-O586050-500MG 500 mg

Oltipraz

Sign In for Pricing
View Details