Rapid ELISA Kit for Mucin 5 Subtype AC (MUC5AC)
Product Specifications
CAS Number
7732-18-5
Product Name Alternative
TBM; MUC5; LeB; Oligomeric Mucus/Gel-Forming; Mucin 5, Subtypes A And C, Tracheobronchial/Gastric; Gastric mucin; Lewis B blood group antigen; Major airway glycoprotein
UniProt
E9PWB6
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Field of Research
Tumor immunity; Infection immunity; Endocrinology; Pulmonology
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Mucin 5 Subtype AC (MUC5AC) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Instant Mucin 5 Subtype AC (MUC5AC) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Instant Mucin 5 Subtype AC (MUC5AC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Mucin 5 Subtype AC (MUC5AC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
1. Prepare all reagents, samples and standards; <br/> 2. Add 50µ L standard or sample and 50µ L Detection Reagent A to each well. Incubate 1 hours at 37° C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 90µ L Substrate Solution. Incubate 10-20 minutes at 37° C; <br/> 5. Add 50µ L Stop Solution. Read at 450nm immediately.<br/>
Assay Performance Time
1h, 10min
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
0.156-10ng/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Instant Mucin 5 Subtype AC (MUC5AC) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Instant Mucin 5 Subtype AC (MUC5AC) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 0.055ng/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Instant Mucin 5 Subtype AC (MUC5AC) . No significant cross-reactivity or interference between Instant Mucin 5 Subtype AC (MUC5AC) and analogues was observed.
Product Name Synonym
Mucin 5 Subtype AC
Method
Double-antibody Sandwich
Organism Species
Mus musculus (Mouse)
Available Sizes
More Discoveries
Explore Other Products
Browse additional items from our catalog