Broad Detection Range ELISA Kit for Fibroblast Growth Factor 21 (FGF21)
Product Specifications
CAS Number
7732-18-5
UniProt
Q8VI80
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Field of Research
Cytokine
Assay Principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Wide-range Fibroblast Growth Factor 21 (FGF21) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Wide-range Fibroblast Growth Factor 21 (FGF21) and unlabeled Wide-range Fibroblast Growth Factor 21 (FGF21) (Standards or samples) with the pre-coated antibody specific to Wide-range Fibroblast Growth Factor 21 (FGF21) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Wide-range Fibroblast Growth Factor 21 (FGF21) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Wide-range Fibroblast Growth Factor 21 (FGF21) in the sample.
Assay Protocol
1. Prepare all reagents, samples and standards; <br/> 2. Add 50µ L standard or sample to each well.<br/> And then add 50µ L prepared Detection Reagent A immediately.<br/> Shake and mix. Incubate 1 hour at 37° C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 90µ L Substrate Solution. Incubate 10-20 minutes at 37° C; <br/> 7. Add 50µ L Stop Solution. Read at 450 nm immediately.<br/>
Assay Performance Time
3h
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
12.35-1,000pg/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Wide-range Fibroblast Growth Factor 21 (FGF21) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Wide-range Fibroblast Growth Factor 21 (FGF21) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 4.77pg/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Wide-range Fibroblast Growth Factor 21 (FGF21) . No significant cross-reactivity or interference between Wide-range Fibroblast Growth Factor 21 (FGF21) and analogues was observed.
Product Name Synonym
Fibroblast Growth Factor 21
Method
Competitive Inhibition
Organism Species
Rattus norvegicus (Rat)
Available Sizes
Frequently Asked Questions
More Discoveries
Explore Other Products
Browse additional items from our catalog