Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Instant ELISA Kit for Melatonin (MT)

Product Specifications

Product Name Alternative

N-Acetyl-5-Methoxytryptamine

Applications

Enzyme-linked immunosorbent assay for Antigen Detection.

Assay Principle

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Instant Melatonin (MT) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Instant Melatonin (MT) and unlabeled Instant Melatonin (MT) (Standards or samples) with the pre-coated antibody specific to Instant Melatonin (MT) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Instant Melatonin (MT) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Instant Melatonin (MT) in the sample.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well. <br/> And then add 50&micro; L prepared Detection Reagent A immediately. <br/> Share and mix. Incubate 50 minutes at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 10 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 90&micro; L Substrate Solution. Incubate 10-20 minutes at 37&deg; C; <br/> 7. Add 50&micro; L Stop Solution. Read at 450nm immediately.<br/>

Assay Performance Time

1H, 10min

Sample Type

Serum, plasma and other biological fluids

Detection Range

6.17 - 500 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Instant Melatonin (MT) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Instant Melatonin (MT) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 2.51pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Instant Melatonin (MT) .<br/> No significant cross-reactivity or interference between Instant Melatonin (MT) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Pan-species (General)

CAS Number

7732-18-5

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Anagyrine
BA5522-5 5mg

Anagyrine

Ask
View Details
PAPOLB CRISPR Knock Out 293T Cell Line (Human)
35992141 1x10<sup>6</sup> cells/1.0ml

PAPOLB CRISPR Knock Out 293T Cell Line (Human)

Ask
View Details
iFluor® 546 Maleimide
WJY0-LS50 Each

iFluor® 546 Maleimide

Ask
View Details
Propargyl-PEG3-CH2CO2H
BIPG1906-01 100 mg

Propargyl-PEG3-CH2CO2H

Ask
View Details
Propargyl-PEG3-CH2CO2H
BIPG1906-02 1 g

Propargyl-PEG3-CH2CO2H

Ask
View Details
Propargyl-PEG3-CH2CO2H
BIPG1906-03 5 g

Propargyl-PEG3-CH2CO2H

Ask
View Details