Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

ELISA Kit for Flotillin 1 (FLOT1)

Product Specifications

CAS Number

7732-18-5

UniProt

O75955

Applications

Enzyme-linked immunosorbent assay for Antigen Detection.

Field of Research

Metabolic pathway

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Flotillin 1 (FLOT1) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Flotillin 1 (FLOT1) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Flotillin 1 (FLOT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Flotillin 1 (FLOT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 90&micro; L Substrate Solution. Incubate 10-20 minutes at 37&deg; C; <br/> 8. Add 50&micro; L Stop Solution. Read at 450nm immediately. <br/>

Assay Performance Time

3h

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Detection Range

0.78-50ng/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Flotillin 1 (FLOT1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Flotillin 1 (FLOT1) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.32ng/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Flotillin 1 (FLOT1) . No significant cross-reactivity or interference between Flotillin 1 (FLOT1) and analogues was observed.

Product Name Synonym

Flotillin 1

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

PCDHB14 (Protocadherin Beta-14)
488195 100 µL

PCDHB14 (Protocadherin Beta-14)

Ask
View Details
ING4
524416-01 100 µL

ING4

Ask
View Details
ING4
524416-02 200 µL

ING4

Ask
View Details
cis-Dehydroosthol
MBS5787061 Inquire

cis-Dehydroosthol

Ask
View Details
RET Y806H Recombinant Human Active Protein Kinase
HY-E70781 1 Each

RET Y806H Recombinant Human Active Protein Kinase

Ask
View Details
Rabbit Matrix Extracellular Phosphoglycoprotein (MEPE) ELISA Kit
EIA06033Rb 1 Kit

Rabbit Matrix Extracellular Phosphoglycoprotein (MEPE) ELISA Kit

Ask
View Details