Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

Product Specifications

Product Name Alternative

TBM; MUC5; LeB; Oligomeric Mucus/Gel-Forming; Mucin 5, Subtypes A And C, Tracheobronchial/Gastric; Gastric mucin; Lewis B blood group antigen; Major airway glycoprotein

UniProt

Q9ESP3

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Tumor immunity; Infection immunity; Endocrinology; Pulmonology

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Mucin 5 Subtype AC (MUC5AC) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Mucin 5 Subtype AC (MUC5AC) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Mucin 5 Subtype AC (MUC5AC) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Detection Range

54.9-40,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 19.3pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Mucin 5 Subtype AC (MUC5AC) . No significant cross-reactivity or interference between Mucin 5 Subtype AC (MUC5AC) and analogues was observed.

Product Name Synonym

Mucin 5 Subtype AC

Method

Double-antibody Sandwich

Organism Species

Rattus norvegicus (Rat)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

H2A2C Rabbit Polyclonal Antibody
JOT-AP10324-01 50ul

H2A2C Rabbit Polyclonal Antibody

Ask
View Details
H2A2C Rabbit Polyclonal Antibody
JOT-AP10324-02 100ul

H2A2C Rabbit Polyclonal Antibody

Ask
View Details
VPS37D AAV Vector (Mouse) (CMV)
50187104 1 µg

VPS37D AAV Vector (Mouse) (CMV)

Ask
View Details
USP18 CRISPRa sgRNA lentivector (set of three targets)(Rat)
49295126 3x 1.0µg DNA

USP18 CRISPRa sgRNA lentivector (set of three targets)(Rat)

Ask
View Details
SARS-CoV-2-IN-25
HY-151267 1 Each

SARS-CoV-2-IN-25

Ask
View Details
PLenti-CMV-GFP-Puro-CYP1A2
PPL00845-4b 1 Each

PLenti-CMV-GFP-Puro-CYP1A2

Ask
View Details