CLIA Kit for Immunoglobulin A2 (IgA2)

Product Specifications

Product Name Alternative

IGHA2; Immunoglobulin Heavy Constant Alpha 2; A2m Marker

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Immunoglobulin A2 (IgA2) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Immunoglobulin A2 (IgA2) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Immunoglobulin A2 (IgA2) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma, saliva and other biological fluids

Detection Range

0.69 - 500 ng/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Immunoglobulin A2 (IgA2) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Immunoglobulin A2 (IgA2) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.31ng/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Immunoglobulin A2 (IgA2) .<br/> No significant cross-reactivity or interference between Immunoglobulin A2 (IgA2) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

CBL Rabbit Polyclonal Antibody
AP06505PU-N 100 µg

CBL Rabbit Polyclonal Antibody

Sign In for Pricing
View Details
Natural Convection Oven BONC-301
BONC-301 1 Unit

Natural Convection Oven BONC-301

Sign In for Pricing
View Details
Recombinant Human FLT-3/FLK-2 Protein (His Tag)
PKSH031603-01 100 µg

Recombinant Human FLT-3/FLK-2 Protein (His Tag)

Sign In for Pricing
View Details
Recombinant Human FLT-3/FLK-2 Protein (His Tag)
PKSH031603-02 1 mg

Recombinant Human FLT-3/FLK-2 Protein (His Tag)

Sign In for Pricing
View Details
Tissue FFPE Sections, Lung
CS708398 5x 5 µm

Tissue FFPE Sections, Lung

Sign In for Pricing
View Details
PEBP4 Antibody
KC-41772-01 50 μL

PEBP4 Antibody

Sign In for Pricing
View Details