CLIA Kit for Interleukin 6 (IL6)

Product Specifications

Product Name Alternative

MGI2-A; MGI2A; HGF; BSF2; HSF; IFNB2; B-Cell Stimulatory Factor-2; Hybridoma/Plasmacytoma Growth Factor; Hepatocyte Stimulating Factor; Cytotoxic T-Cell Differentiation Factor

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 6 (IL6) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 6 (IL6) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 6 (IL6) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma and other biological fluids

Detection Range

2.74 - 2000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Interleukin 6 (IL6) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Interleukin 6 (IL6) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 1.18pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Interleukin 6 (IL6) .<br/> No significant cross-reactivity or interference between Interleukin 6 (IL6) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Bos taurus; Bovine (Cattle)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Lin28A Recombinant Rabbit monoclonal Antibody
HA750410 100 µL

Lin28A Recombinant Rabbit monoclonal Antibody

Sign In for Pricing
View Details
POTEF Human Gene Knockout Kit (CRISPR)
KN416378 1 Kit

POTEF Human Gene Knockout Kit (CRISPR)

Sign In for Pricing
View Details
Annexin A3 (ANXA3) Rabbit Polyclonal Antibody
AP12481PU-N 400 µL

Annexin A3 (ANXA3) Rabbit Polyclonal Antibody

Sign In for Pricing
View Details
RPL15 (NM_002948) Human Over-expression Lysate
LY418995 100 µg

RPL15 (NM_002948) Human Over-expression Lysate

Sign In for Pricing
View Details
Benzo[a]pyrene-6,12-quinone
TRC-B205870-1MG 1 mg

Benzo[a]pyrene-6,12-quinone

Sign In for Pricing
View Details
CD40, Mouse (FGK45.5), CF568 conjugate, 0.1mg/mL
BNC682005-100 1x 100 µL

CD40, Mouse (FGK45.5), CF568 conjugate, 0.1mg/mL

Sign In for Pricing
View Details