Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Fibroblast Growth Factor 9 (FGF9)

Product Specifications

Product Name Alternative

GAF; HBFG9; Glia-Activating Factor; Heparin-Binding Growth Factor 9

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 9 (FGF9) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 9 (FGF9) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 9 (FGF9) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma and other biological fluids

Detection Range

5.49 - 4000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Fibroblast Growth Factor 9 (FGF9) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Fibroblast Growth Factor 9 (FGF9) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 2.49pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 9 (FGF9) .<br/> No significant cross-reactivity or interference between Fibroblast Growth Factor 9 (FGF9) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

SNX17 (N-term) Rabbit Polyclonal Antibody
AP53973PU-N 400 µL

SNX17 (N-term) Rabbit Polyclonal Antibody

Sign In for Pricing
View Details
Frozen Tissue Sections, Kidney
CS631540 5x 5 µm

Frozen Tissue Sections, Kidney

Sign In for Pricing
View Details
(Z)-11-Octadecenoic Acid (Solution in Ethanol)
TRC-O860075-250MG 250 mg

(Z)-11-Octadecenoic Acid (Solution in Ethanol)

Sign In for Pricing
View Details
4-Hydroxy-2-hexenal Antibody
SMC-536D 100 µg

4-Hydroxy-2-hexenal Antibody

Sign In for Pricing
View Details
EN1 Rabbit Polyclonal Antibody
TA368239 100 µL

EN1 Rabbit Polyclonal Antibody

Sign In for Pricing
View Details
N-Acetylglycine
TRC-A178260-5G 5 g

N-Acetylglycine

Sign In for Pricing
View Details