Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Interleukin 28A (IL28A)

Product Specifications

Product Name Alternative

IFNL2; Interferon, Lambda 2; Cytokine Zcyto20

UniProt

Q4VK74

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Cytokine; Infection immunity

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 28A (IL28A) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 28A (IL28A) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 28A (IL28A) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

1.37-1,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Interleukin 28A (IL28A) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Interleukin 28A (IL28A) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.52pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 28A (IL28A) . No significant cross-reactivity or interference between Interleukin 28A (IL28A) and analogues was observed.

Product Name Synonym

Interleukin 28A

Method

Double-antibody Sandwich

Organism Species

Mus musculus (Mouse)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

Rat SELL Antibody Pair Set
E-KAB-0361 50 µL & 100 µg

Rat SELL Antibody Pair Set

Sign In for Pricing
View Details
KIAA0323 (KHNYN) (NM_001290257) Human Tagged ORF Clone
RG239294 10 µg

KIAA0323 (KHNYN) (NM_001290257) Human Tagged ORF Clone

Sign In for Pricing
View Details
Flupyradifurone
TRC-F598615-25MG 25 mg

Flupyradifurone

Sign In for Pricing
View Details
CT45A5 (NM_001007551) Human Over-expression Lysate
LY423509 100 µg

CT45A5 (NM_001007551) Human Over-expression Lysate

Sign In for Pricing
View Details
CD8 (RIV11), 0.2mg/mL
BNUB0333-500 1x 500 µL

CD8 (RIV11), 0.2mg/mL

Sign In for Pricing
View Details
Tissue Total RNA, Esophagus
CR560386 5 µg

Tissue Total RNA, Esophagus

Sign In for Pricing
View Details