CLIA Kit for Myostatin (MSTN)
Product Specifications
Product Name Alternative
GDF8; Growth Differentiation Factor 8
UniProt
O35312
Applications
Chemiluminescent immunoassay for Antigen Detection.
Field of Research
Cytokine; Metabolic pathway; Bone metabolism
Assay Principle
The microplate provided in this kit has been pre-coated with an antibody specific to Myostatin (MSTN) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Myostatin (MSTN) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Myostatin (MSTN) level in the sample or standard.
Assay Protocol
1. Prepare all reagents, samples and standards; <br/> 2. Add 100µ L standard or sample to each well. Incubate 2 hours at 37° C; <br/> 3. Aspirate and add 100µ L prepared Detection Reagent A. Incubate 1 hour at 37° C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100µ L Substrate Solution. Incubate 10 minutes at 37° C; <br/> 8. Read RLU value immediately.<br/>
Assay Performance Time
2h, 40min
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Detection Range
54.9-40,000pg/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Myostatin (MSTN) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Myostatin (MSTN) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 18.7pg/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Myostatin (MSTN) . No significant cross-reactivity or interference between Myostatin (MSTN) and analogues was observed.
Product Name Synonym
Myostatin
Method
Double-antibody Sandwich
Organism Species
Rattus norvegicus (Rat)
Available Sizes