CLIA Kit for Interleukin 31 (IL31)

Product Specifications

UniProt

Q6EAL8

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Cytokine; Tumor immunity; Infection immunity; Dermatology

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 31 (IL31) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 31 (IL31) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 31 (IL31) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

0.55-400pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Interleukin 31 (IL31) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Interleukin 31 (IL31) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.19pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 31 (IL31) . No significant cross-reactivity or interference between Interleukin 31 (IL31) and analogues was observed.

Product Name Synonym

Interleukin 31

Method

Double-antibody Sandwich

Organism Species

Mus musculus (Mouse)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

SIAE Antibody
MBS9524428-01 0.04 mL

SIAE Antibody

Ask
View Details
SIAE Antibody
MBS9524428-02 0.1 mL

SIAE Antibody

Ask
View Details
SIAE Antibody
MBS9524428-03 0.2 mL

SIAE Antibody

Ask
View Details
SIAE Antibody
MBS9524428-04 5x 0.2 mL

SIAE Antibody

Ask
View Details
Lentiviral mouse Fgf21 shRNA (UAS) - Lentiviral mouse Fgf21 shRNA (UAS) (100)
GTR15228402 1 Vial

Lentiviral mouse Fgf21 shRNA (UAS) - Lentiviral mouse Fgf21 shRNA (UAS) (100)

Ask
View Details
5-Hydroxyindole-3-acetic Acid-13C3
TRC-H953604-0.5MG 0.5 mg

5-Hydroxyindole-3-acetic Acid-13C3

Ask
View Details