Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Resistin (RETN)

Product Specifications

Product Name Alternative

ADSF; FIZZ3; RETN1; RSTN; XCP1; Adipose tissue-specific secretory factor; C/EBP-epsilon-regulated myeloid-specific secreted cysteine-rich protein; Cysteine-rich secreted FIZZ3

UniProt

Q99P87

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Metabolic pathway; Endocrinology; Cardiovascular biology

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Resistin (RETN) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Resistin (RETN) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Resistin (RETN) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

54.9-40,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Resistin (RETN) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Resistin (RETN) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 18.6pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Resistin (RETN) . No significant cross-reactivity or interference between Resistin (RETN) and analogues was observed.

Product Name Synonym

Resistin

Method

Double-antibody Sandwich

Organism Species

Mus musculus (Mouse)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

GPR136 (OPN5) (NM_181744) Human Tagged Lenti ORF Clone
RC214800L4 10 µg

GPR136 (OPN5) (NM_181744) Human Tagged Lenti ORF Clone

Ask
View Details
ATP2C2 Peptide
DF9312-BP 1 mg

ATP2C2 Peptide

Ask
View Details
Human FAM167A shRNA Plasmid
abx963152-01 150 µg

Human FAM167A shRNA Plasmid

Ask
View Details
Human FAM167A shRNA Plasmid
abx963152-02 300 µg

Human FAM167A shRNA Plasmid

Ask
View Details
Six1 Polyclonal Antibody
UB-GEN-15229 100 µL

Six1 Polyclonal Antibody

Ask
View Details
STAT 5, phosphorylated (Tyr694) (Signal Transducer and Activator of Transcription 5)
MBS626193-01 0.1 mL

STAT 5, phosphorylated (Tyr694) (Signal Transducer and Activator of Transcription 5)

Ask
View Details