Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Prolactin (PRL)

Product Specifications

Product Name Alternative

LTH; Luteotropic Hormone

UniProt

Q5THQ0

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Endocrinology; Reproductive science; Genetic science; Hormone metabolism

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Prolactin (PRL) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Prolactin (PRL) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Prolactin (PRL) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

0.41-300ng/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Prolactin (PRL) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Prolactin (PRL) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.19ng/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Prolactin (PRL) . No significant cross-reactivity or interference between Prolactin (PRL) and analogues was observed.

Product Name Synonym

Prolactin

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

3-Phenylisonicotinic Acid
TRC-P399700-10MG 10 mg

3-Phenylisonicotinic Acid

Sign In for Pricing
View Details
Synapsin I (SYN1) pSer9 Rabbit Polyclonal Antibody
AP02514PU-N 100 µL

Synapsin I (SYN1) pSer9 Rabbit Polyclonal Antibody

Sign In for Pricing
View Details
Slc41a2 Mouse Gene Knockout Kit (CRISPR)
KN516118 1 Kit

Slc41a2 Mouse Gene Knockout Kit (CRISPR)

Sign In for Pricing
View Details
P53 Tumor Suppressor Protein (TP53/2092R), 0.2mg/mL
BNUB2092-100 1x 100 µL

P53 Tumor Suppressor Protein (TP53/2092R), 0.2mg/mL

Sign In for Pricing
View Details
Tissue FFPE Sections, Ovary
CS805486 5x 5 µm

Tissue FFPE Sections, Ovary

Sign In for Pricing
View Details
GDC-0879 Hydrochloride
TRC-G299980-250MG 250 mg

GDC-0879 Hydrochloride

Sign In for Pricing
View Details