Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for E-selectin

Product Specifications

Product Name Alternative

CD62E; CD62-E; E-Selectin; ELAM; ELAM1; ESEL; SEL-E; E-LAM; E-LAM1; E-SEL; LECAM2; Endothelial Leukocyte Adhesion Molecule 1; CD62 Antigen-Like Family Member E

UniProt

P98105

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Signal transduction; CD & Adhesion molecule; Tumor immunity; Infection immunity

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to E-selectin. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to E-selectin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the E-selectin level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

2.74-2,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level E-selectin were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level E-selectin were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 1.24pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of E-selectin. No significant cross-reactivity or interference between E-selectin and analogues was observed.

Product Name Synonym

E-selectin

Method

Double-antibody Sandwich

Organism Species

Rattus norvegicus (Rat)

Available Sizes

More Discoveries

Explore Other Products

Browse additional items from our catalog

Neurogranin (NRGN) CytoSection
TS401209P5 25 Slides

Neurogranin (NRGN) CytoSection

Sign In for Pricing
View Details
Human SEMA5B (Semaphorin 5B) ELISA Kit
EH24541 96 Tests

Human SEMA5B (Semaphorin 5B) ELISA Kit

Sign In for Pricing
View Details
ASF1A Human Over-expression Lysate
orb1357032 100 µg

ASF1A Human Over-expression Lysate

Sign In for Pricing
View Details
Sheep Immunoglobulin M, IgM ELISA Kit
MBS1609152 96 Well

Sheep Immunoglobulin M, IgM ELISA Kit

Sign In for Pricing
View Details
HeLa S3 Luciferase Reporter Cell Line
ABC-RC612H 1 Vial

HeLa S3 Luciferase Reporter Cell Line

Sign In for Pricing
View Details
ZNF85 (Zinc Finger Protein 85, HPF4, HTF1, MGC78566) (PE)
MBS6184190-01 0.1 mL

ZNF85 (Zinc Finger Protein 85, HPF4, HTF1, MGC78566) (PE)

Sign In for Pricing
View Details