Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

ELISA Kit for Albumin (ALB)

Product Specifications

CAS Number

7732-18-5

Product Name Alternative

Serum albumin

Applications

Enzyme-linked immunosorbent assay for Antigen Detection.

Field of Research

Tumor immunity; Infection immunity; Hematology; Hepatology; Nutrition metabolism

Assay Principle

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Albumin (ALB) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Albumin (ALB) and unlabeled Albumin (ALB) (Standards or samples) with the pre-coated antibody specific to Albumin (ALB) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Albumin (ALB) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Albumin (ALB) in the sample.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well.<br/> &nbsp; &nbsp; &nbsp; &nbsp; And then add 50&micro; L prepared Detection Reagent A immediately.<br/> &nbsp; &nbsp; &nbsp; &nbsp; Shake and mix. Incubate 1 hour at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 90&micro; L Substrate Solution. Incubate 10-20 minutes at 37&deg; C; <br/> 7. Add 50&micro; L Stop Solution. Read at 450 nm immediately.<br/>

Assay Performance Time

2h

Sample Type

Serum, plasma and other biological fluids

Detection Range

1.23-100ug/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Albumin (ALB) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Albumin (ALB) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.57ug/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Albumin (ALB) . No significant cross-reactivity or interference between Albumin (ALB) and analogues was observed.

Product Name Synonym

Albumin

Method

Competitive Inhibition

Organism Species

Mus musculus (Mouse)

Available Sizes

Frequently Asked Questions

More Discoveries

Explore Other Products

Browse additional items from our catalog

CD11a (Cris-3), CF488A conjugate, 0.1mg/mL
BNC880151-100 1x 100 µL

CD11a (Cris-3), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
WT1 (Wilm's Tumor 1) (6F-H2), CF555 conjugate, 0.1mg/mL
BNC550856-100 1x 100 µL

WT1 (Wilm's Tumor 1) (6F-H2), CF555 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Smooth Muscle Actin (1A4), CF640R conjugate, 0.1mg/mL
BNC400665-500 1x 500 µL

Smooth Muscle Actin (1A4), CF640R conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Beta-2 Microglobulin (Renal Failure &Tumor Marker) (rB2M/961), CF488A conjugate, 0.1mg/mL
BNC881537-100 1x 100 µL

Beta-2 Microglobulin (Renal Failure &Tumor Marker) (rB2M/961), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details
CD54 (W-CAM-1; same as Wehi-CAM-1 or 1H4), CF568 conjugate, 0.1mg/mL
BNC680988-500 1x 500 µL

CD54 (W-CAM-1; same as Wehi-CAM-1 or 1H4), CF568 conjugate, 0.1mg/mL

Sign In for Pricing
View Details
Blood Group Antigen B (CD173) (HEB-20), CF488A conjugate, 0.1mg/mL
BNC880296-500 1x 500 µL

Blood Group Antigen B (CD173) (HEB-20), CF488A conjugate, 0.1mg/mL

Sign In for Pricing
View Details