Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Necrosis vs Apoptosis Assay Kit

This kit simultaneously detects both cell death due to both apoptosis and necrosis. It can be used to assess the effects of novel therapeutic agents on cell health. Analyze the fluorescent signal using fluorescence microscopy or flow cytometry.

Product Specifications

Specifications

FAM-VAD-FMK, 7-AAD

Target

Caspases, GC-rich DNA

Label

ICT

Cell Type

Jurkat; U-2 OS

Type

Cell Viabiity

Detection Method

Flow cytometry, Fluorescence microscope

Wavelength

FAM-FLICA – 492 nm / 529 nm 7-AAD – 546 nm / 647 nm

Assay Protocol

1. Prepare samples and controls., 2. Dilute 10X Apoptosis Wash Buffer 1:10 with diH20., 3. Reconstitute FLICA with 50 μL DMSO., 4. Dilute FLICA 1:5 by adding 200 μL PBS., 5. Add diluted FLICA to each sample at 1:30 – 1:60. For example, to stain at 1:30, add 10 μL to 290 μL of cultured cells. To stain at 1:60, add 5 μL to 295 μL of cultured cells., 6. Incubate approximately 1 hour., 7. Remove media and wash cells 3 times: add 1X Apoptosis Wash Buffer and spin cells., 8. If desired, label with additional stains, such as Hoechst, 7-AAD, or an antibody., 9. If desired, fix or embed cells., 10. Analyze with a fluorescence microscope, fluorescence platereader, or flow cytometer. SR-FLICA excites at 550-580 nm and emits at 590-600 nm.

Sample Type

Cell culture

Components

Kit 9148: 100-200 tests, FAM-FLICA Poly Caspase Reagent (FAM-VAD-FMK), 4 vials, #637, 7-Aminoactinomycin D (7-AAD) vital dye, 2 0.26 mg vials, #6163, 10X Apoptosis Wash Buffer, 2 60 mL bottles, #634, Fixative, 6 mL, #636, Kit Manual

Shipping Conditions

Ships overnight (domestic), International Priority Shipping

Storage Temperature

2-8°C

Target Description

Assessment of cellular cytotoxicity levels associated with cytolytic activity of T lymphocytes or natural killer cells is an important aspect of immunobiology related research. Early assays developed to assess cytolytic activity utilized the release of 51Cr from membrane compromised target cells, which were passively loaded with this radioactive indicator prior to exposure to the cytotoxic agent or cells. A major draw-back to these 51Cr release assays is their reliance on the use of a radioactive isotope with its associated disposal and safe handling issues. Additionally, chromium uptake methods suffer from variabilities in target cell preloading inconsistencies as Well the tendency to spontaneously release the chromium isotope into the media in the absence of any cytotoxicity stimulus. Assessing potential cytotoxicity properties of chemical and biological agents is a mandatory requirement for the safe distribution of pharmaceuticals, vaccines, or additives associated with food product formulations. Early identification of unintended drug, vaccine, or chemical associated cytotoxicity properties is always an early priority of initial FDA approval testing protocols. With cellular cytotoxicity assessment playing a central role in countless research and environmental safety studies, there is an ever present need for simple, straightforward analysis methods like the Necrosis vs Apoptosis Assay developed by Immunochemistry Technologies, LLC (ICT). ICT’s Necrosis vs Apoptosis Assay simultaneously detects both apoptosis associated cytotoxicity events as Well as cell death due to necrosis. Apoptotic cells are identified using ICT’s Fluorescent Labeled Inhibitor of CAspases (FLICA®) reagent probe. The FAM-FLICA® probe covalently binds to active caspase enzymes, which are up-regulated during apoptosis, thus clearly labeling apoptotic cells for subsequent analysis. Non-apoptotic cells will not contain the active caspase enzymes required for FAM-FLICA® to remain covalently bound within the cell structure. Loss of the integrity of the cell membrane, indicative of necrosis or late stage apoptosis, is detected using the vital staining dye, 7-aminoactinomycin D (7-AAD), a red fluorescing live/dead stain. This dye easily penetrates cell membrane-compromised cells, binding tightly to GC rich regions of the DNA. 7-AAD will not label cells in early stages of apoptosis, as their cell membranes are still intact and are capable of excluding 7-AAD. As caspases are active during early apoptosis, combining FAM-FLICA® with 7-AAD can provide a more detailed picture of the overall health of the cell population by revealing the percentage of cells that are 7-AAD-negative (membrane intact live cells) and yet FAM-FLICA® positive (apoptotic) (Figures 3-6). FAM-FLICA® probes optimally excite at 488-492 nm with maximal emission at 515-535 nm. The vital staining dye 7-AAD optimally excites at 546 nm and emits at 647 nm. This significant difference in fluorescence emission wavelength between the green FAM (carboxyfluorescein) label on the FAM-FLICA® probe and the red 7-AAD vital dye simplifies flow cytometer gating and compensation. The FAM-FLICA® probe (apoptosis) is monitored on the FL-1 channel, while 7-AAD (necrosis) is monitored on FL-3. Combining the use of ICT’s FAM-FLICA® apoptosis detection probe with a membrane integrity dye like 7-AAD makes it easy to distinguish between necrosis and apoptosis within a single sample.
Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

CAY10535
MBS5785043 Inquire

CAY10535

Ask
View Details
Lentiviral human PRKCB sgRNA gene knockout kit - Lentiviral human PRKCB sgRNA gene knockout kit (plasmid)
GTR15359747 1 Vial

Lentiviral human PRKCB sgRNA gene knockout kit - Lentiviral human PRKCB sgRNA gene knockout kit (plasmid)

Ask
View Details
MHP 133 50mg
A20058-50 50 mg

MHP 133 50mg

Ask
View Details
SSB Polyclonal Antibody
MBS8525406-01 0.1 mg

SSB Polyclonal Antibody

Ask
View Details
SSB Polyclonal Antibody
MBS8525406-02 0.1 mL (AF635)

SSB Polyclonal Antibody

Ask
View Details
SSB Polyclonal Antibody
MBS8525406-03 0.1 mL (AF610)

SSB Polyclonal Antibody

Ask
View Details