RYR2 ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Ryanodine Receptor 2, Cardiac (RYR2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Ryanodine Receptor 2, Cardiac (RYR2) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Ryanodine receptor 2
Gene Aliases
ARVC2; ARVD2; Cardiac muscle ryanodine receptor; cardiac muscle ryanodine receptor-calcium release channel; cardiac-type ryanodine receptor; islet-type ryanodine receptor; kidney-type ryanodine receptor; ryanodine receptor 2; ryanodine receptor 2 (cardiac) ; RyR; RYR-2; type 2 ryanodine receptor; VACRDS; VTSIP.
Gene ID
6262
Accession Number
NP_001026.2
Reactivity
Homo sapiens|Human
Target
Calcium channel that mediates the release of Ca (2+) from the sarcoplasmic reticulum into the cytoplasm and thereby plays a key role in triggering cardiac muscle contraction. Aberrant channel activation can lead to cardiac arrhythmia. In cardiac myocytes, calcium release is triggered by increased Ca (2+) levels due to activation of the L-type calcium channel CACNA1C. The calcium channel activity is modulated by formation of heterotetramers with RYR3. Required for cellular calcium ion homeostasis. Required for embryonic heart development.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ryanodine Receptor 2, Cardiac (RYR2) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ryanodine Receptor 2, Cardiac (RYR2) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ryanodine Receptor 2, Cardiac (RYR2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Ryanodine Receptor 2, Cardiac (RYR2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
0.312-20ng/mL
Sensitivity
< 0.116ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount RYR2 Microplate 96 Wells (12 x 8 Well strips) RYR2 Lyophilized Standard 2 100X RYR2 HRP-Detector Anitbody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount RYR2 Microplate 96 Wells (12 x 8 Well strips) RYR2 Microplate 96 Wells (12 x 8 Well strips) RYR2 Lyophilized Standard 2 RYR2 Lyophilized Standard 2 100X RYR2 HRP-Detector Anitbody 1 x 120 uL 100X RYR2 HRP-Detector Anitbody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
NCBI Gene Symbol
RYR2
Protein Name
Ryanodine receptor 2
Gene Name URL
RYR2
Nucleotide Accession Number
NM_001035.2
Frequently Asked Questions
More Discoveries
Explore Other Products
Browse additional items from our catalog