Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Constitutive Androstane Receptor (CAR) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Constitutive Androstane Receptor (CAR) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Nuclear receptor subfamily 1, group I, member 3
Gene Aliases
CAR; constitutive androstane receptor; nuclear receptor constitutive active receptor; nuclear receptor subfamily 1 group I member 3; strain Fischer nuclear receptor (CAR) .
Gene ID
65035
Accession Number
NP_075230.1
Reactivity
Rat|Rattus norvegicus
Target
Binds and transactivates the retinoic acid response elements that control expression of the retinoic acid receptor beta 2 and alcohol dehydrogenase 3 genes. Transactivates both the phenobarbital responsive element module of the human CYP2B6 gene and the CYP3A4 xenobiotic response element (By similarity) .
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Constitutive Androstane Receptor (CAR) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Constitutive Androstane Receptor (CAR) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Constitutive Androstane Receptor (CAR), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Constitutive Androstane Receptor (CAR) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Detection Range
0.156-10ng/mL
Sensitivity
< 0.060ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount NR1I3 Microplate 96 Wells (12 x 8 Well strips) NR1I3 Lyophilized Standard 2 100X NR1I3 HRP-Detector Anitbody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 2 mL Stop Solution 1 x 20 mL Component Amount Component Amount NR1I3 Microplate 96 Wells (12 x 8 Well strips) NR1I3 Microplate 96 Wells (12 x 8 Well strips) NR1I3 Lyophilized Standard 2 NR1I3 Lyophilized Standard 2 100X NR1I3 HRP-Detector Anitbody 1 x 120 uL 100X NR1I3 HRP-Detector Anitbody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 2 mL TMB Substrate 1 x 2 mL Stop Solution 1 x 20 mL Stop Solution 1 x 20 mL
NCBI Gene Symbol
Nr1i3
Protein Name
Nuclear receptor subfamily 1 group I member 3
Gene Name URL
Nr1i3
Nucleotide Accession Number
NM_022941.4