RELN ELISA Kit (Mouse)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Reelin (RELN) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Reelin (RELN) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Reelin
Gene Aliases
Extracellular matrix serine protease; reeler; Reeler protein; reelin; rl.
Gene ID
19699
Accession Number
NP_001297393.1
Reactivity
Mouse|Mus musculus
Target
Extracellular matrix serine protease that plays a role in layering of neurons in the cerebral cortex and cerebellum. Regulates microtubule function in neurons and neuronal migration. Affects migration of sympathetic preganglionic neurons in the spinal cord, where it seems to act as a barrier to neuronal migration. Enzymatic activity is important for the modulation of cell adhesion. Binding to the extracellular domains of lipoprotein receptors VLDLR and LRP8/APOER2 induces tyrosine phosphorylation of DAB1 and modulation of TAU phosphorylation.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Reelin (RELN) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Reelin (RELN) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Reelin (RELN), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Reelin (RELN) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Detection Range
0.156-10ng/mL
Recovery
Matrix Recovery range (%) Average (%) Serum (n=5) 82-89 86 EDTA Plasma (n=5) 96-104 101 Heparin Plasma (n=5) 83-99 94 Matrix Recovery range (%) Average (%) Matrix Recovery range (%) Average (%) Serum (n=5) 82-89 86 Serum (n=5) 82-89 86 EDTA Plasma (n=5) 96-104 101 EDTA Plasma (n=5) 96-104 101 Heparin Plasma (n=5) 83-99 94 Heparin Plasma (n=5) 83-99 94
Sensitivity
6.1 pg/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-RELN Microplate 96 Wells (12 x 8 Well strips) RELN Lyophilized Standard 2 100X Biotinylated RELN Detector Antibody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL Stop Solution 1 x 6 mL TMB Substrate 1 x 9 mL Component Amount Component Amount Anti-RELN Microplate 96 Wells (12 x 8 Well strips) Anti-RELN Microplate 96 Wells (12 x 8 Well strips) RELN Lyophilized Standard 2 RELN Lyophilized Standard 2 100X Biotinylated RELN Detector Antibody 1 x 120 uL 100X Biotinylated RELN Detector Antibody 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL 100X Avidin-HRP Conjugate 1 x 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL
Specificity
This assay has high sensitivity and excellent specificity for detection of Reelin (RL) . No significant cross-reactivity or interference between Reelin (RL) and analogues was observed.
Protein Length
3461
NCBI Gene Symbol
Reln
Protein Name
Reelin
Gene Name URL
Reln
Nucleotide Accession Number
NM_001310464.1
Curated Selection
Explore Other Products