Mapt High Sensitivity ELISA Kit (Mouse)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level High Sensitive Tau Protein (MAPT) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level High Sensitive Tau Protein (MAPT) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Microtubule-associated protein tau
Gene Aliases
AI413597; AW045860; microtubule-associated protein tau; Mta; Mtapt; neurofibrillary tangle protein; paired helical filament-tau; PHF-tau; Ta; Tau.
Gene ID
17762
Accession Number
NP_001033698.1
Reactivity
Mouse|Mus musculus
Target
Promotes microtubule assembly and stability, and might be involved in the establishment and maintenance of neuronal polarity. The C-terminus binds axonal microtubules while the N-terminus binds neural plasma membrane components, suggesting that tau functions as a linker protein between both. Axonal polarity is predetermined by tau localization (in the neuronal cell) in the domain of the cell body defined by the centrosome. The short isoforms allow plasticity of the cytoskeleton whereas the longer isoforms may preferentially play a role in its stabilization.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Tau Protein (MAPT) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Tau Protein (MAPT) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Tau Protein (MAPT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive Tau Protein (MAPT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Detection Range
7.8-500pg/mL
Recovery
Matrix Recovery range (%) Average (%) Serum (n=5) 85-98 94 EDTA Plasma (n=5) 88-95 91 Heparin Plasma (n=5) 96-105 102 Matrix Recovery range (%) Average (%) Matrix Recovery range (%) Average (%) Serum (n=5) 85-98 94 Serum (n=5) 85-98 94 EDTA Plasma (n=5) 88-95 91 EDTA Plasma (n=5) 88-95 91 Heparin Plasma (n=5) 96-105 102 Heparin Plasma (n=5) 96-105 102
Sensitivity
2.5 pg/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-Mapt Microplate 96 Wells (12 x 8 Well Strips) Mapt Lyophilized Standard 2 100X Biotinylated Mapt Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-Mapt Microplate 96 Wells (12 x 8 Well Strips) Anti-Mapt Microplate 96 Wells (12 x 8 Well Strips) Mapt Lyophilized Standard 2 Mapt Lyophilized Standard 2 100X Biotinylated Mapt Detector Antibody 120 uL 100X Biotinylated Mapt Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Specificity
This assay has high sensitivity and excellent specificity for detection of Microtubule Associated Protein Tau (MAPt) . No significant cross-reactivity or interference between Microtubule Associated Protein Tau (MAPt) and analogues was observed.
NCBI Gene Symbol
Mapt
Protein Name
Microtubule-associated protein tau
Gene Name URL
Mapt
Nucleotide Accession Number
NM_001038609.2
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items