APOB48 High Sensitivity ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level High Sensitive Apolipoprotein B48 (APOB48) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level High Sensitive Apolipoprotein B48 (APOB48) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Apolipoprotein B
Gene Aliases
ApoB-100; apoB-48; apolipoprotein B (including Ag (x) antigen) ; apolipoprotein B-100; apolipoprotein B48; FCHL2; FLDB; LDLCQ4.
Gene ID
338
Reactivity
Homo sapiens|Human
Target
Apolipoprotein B is a major protein constituent of chylomicrons (apo B-48), LDL (apo B-100) and VLDL (apo B-100) . Apo B-100 functions as a recognition signal for the cellular binding and internalization of LDL particles by the apoB/E receptor.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Apolipoprotein B48 (APOB48) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Apolipoprotein B48 (APOB48) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Apolipoprotein B48 (APOB48), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive Apolipoprotein B48 (APOB48) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma and other biological fluids
Detection Range
2.4-150ng/mL
Recovery
Matrix Recovery range (%) Average (%) _x005F Serum (n=5) 82-91 88 _x005F EDTA Plasma (n=5) 86-101 95 _x005F Heparin Plasma (n=5) 98-105 102 _x005F Matrix Recovery range (%) Average (%) Matrix Recovery range (%) Average (%) Serum (n=5) 82-91 88 Serum (n=5) 82-91 88 EDTA Plasma (n=5) 86-101 95 EDTA Plasma (n=5) 86-101 95 Heparin Plasma (n=5) 98-105 102 Heparin Plasma (n=5) 98-105 102
Sensitivity
< 1.1 ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount _x005F Anti-APOB48 Microplate 96 Wells (12 x 8 Well Strips) _x005F APOB48 Lyophilized Standard 2 _x005F 100X Biotinylated APOB48 Detector Antibody 120 uL _x005F Avidin/HRP Conjugate 120 uL _x005F Standard Diluent 1 x 20 mL _x005F Detector Antibody Diluent 1 x 12 mL _x005F Conjugate Diluent 1 x 12 mL _x005F 30X Wash Buffer 1 x 20 mL _x005F TMB Substrate 1 x 9 mL _x005F Stop Solution 1 x 6 mL _x005F Component Amount Component Amount Anti-APOB48 Microplate 96 Wells (12 x 8 Well Strips) Anti-APOB48 Microplate 96 Wells (12 x 8 Well Strips) APOB48 Lyophilized Standard 2 APOB48 Lyophilized Standard 2 100X Biotinylated APOB48 Detector Antibody 120 uL 100X Biotinylated APOB48 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Specificity
This assay has high sensitivity and excellent specificity for detection of Apolipoprotein B48 (APOB48) . No significant cross-reactivity or interference between Apolipoprotein B48 (APOB48) and analogues was observed.
NCBI Gene Symbol
APOB
Protein Name
Apolipoprotein B-100
Gene Name URL
APOB
Frequently Asked Questions
More Discoveries
Explore Other Products
Browse additional items from our catalog