CRP High Sensitivity ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level High Sensitive C Reactive Protein (CRP) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level High Sensitive C Reactive Protein (CRP) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
C-reactive protein
Gene Aliases
C-reactive protein; C-reactive protein, pentraxin-related; pentraxin 1; PTX1.
Gene ID
1401
Accession Number
NP_000558.2
Reactivity
Homo sapiens|Human
Target
Displays several functions associated with host defense: it promotes agglutination, bacterial capsular swelling, phagocytosis and complement fixation through its calcium-dependent binding to phosphorylcholine. Can interact with DNA and histones and may scavenge nuclear material released from damaged circulating cells.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive C Reactive Protein (CRP) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive C Reactive Protein (CRP) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive C Reactive Protein (CRP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive C Reactive Protein (CRP) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates, cell lysates, urine, cerebrospinal fluid, cell culture supernates and other biological fluids.
Detection Range
62.5-4,000pg/mL
Recovery
Matrix Recovery range (%) Average (%) Serum (n=5) 78-92 88 EDTA Plasma (n=5) 84-101 88 Heparin Plasma (n=5) 79-96 83 Matrix Recovery range (%) Average (%) Matrix Recovery range (%) Average (%) Serum (n=5) 78-92 88 Serum (n=5) 78-92 88 EDTA Plasma (n=5) 84-101 88 EDTA Plasma (n=5) 84-101 88 Heparin Plasma (n=5) 79-96 83 Heparin Plasma (n=5) 79-96 83
Sensitivity
23.3 pg/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-CRP Microplate 96 Wells (12 x 8 Well Strips) CRP Lyophilized Standard 2 100X Biotinylated CRP Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-CRP Microplate 96 Wells (12 x 8 Well Strips) Anti-CRP Microplate 96 Wells (12 x 8 Well Strips) CRP Lyophilized Standard 2 CRP Lyophilized Standard 2 100X Biotinylated CRP Detector Antibody 120 uL 100X Biotinylated CRP Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Specificity
This assay has high sensitivity and excellent specificity for detection of C Reactive Protein (CRP) . No significant cross-reactivity or interference between C Reactive Protein (CRP) and analogues was observed.
NCBI Gene Symbol
CRP
Protein Name
C-reactive protein
Gene Name URL
CRP
Nucleotide Accession Number
NM_000567.2
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items