PCNT ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Pericentrin (PCNT) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Pericentrin (PCNT) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Pericentrin
Gene Aliases
KEN; kendrin; MOPD2; PCN; PCNT2; PCNTB; PCTN2; pericentrin; pericentrin-2; pericentrin-380; pericentrin-B; SCKL4.
Gene ID
5116
Accession Number
NP_001302458
Reactivity
Homo sapiens|Human
Target
Integral component of the filamentous matrix of the centrosome involved in the initial establishment of organized microtubule arrays in both mitosis and meiosis. Plays a role, together with DISC1, in the microtubule network formation. Is an integral component of the pericentriolar material (PCM) . May play an important role in preventing premature centrosome splitting during interphase by inhibiting NEK2 kinase activity at the centrosome.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pericentrin (PCNT) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Pericentrin (PCNT) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pericentrin (PCNT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Pericentrin (PCNT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Detection Range
0.312-20ng/mL
Recovery
Matrix Recovery Range (%) Average (%) 92-101 96 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) 92-101 96 92-101 96
Sensitivity
< 0.119 ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-PCNT Microplate 96 Wells (12 x 8 Well Strips) PCNT Lyophilized Standard 2 x 20 ng 100X Biotinylated PCNT Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-PCNT Microplate 96 Wells (12 x 8 Well Strips) Anti-PCNT Microplate 96 Wells (12 x 8 Well Strips) PCNT Lyophilized Standard 2 x 20 ng PCNT Lyophilized Standard 2 x 20 ng 100X Biotinylated PCNT Detector Antibody 120 uL 100X Biotinylated PCNT Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Notes
Formerly GWB-KBBVY5
Specificity
This assay has high sensitivity and excellent specificity for detection of Pericentrin (PCNT) . No significant cross-reactivity or interference between Pericentrin (PCNT) and analogues was observed.
Protein Length
3336
NCBI Gene Symbol
PCNT
Protein Name
Pericentrin
Gene Name URL
PCNT
Nucleotide Accession Number
NM_001315529.1