MAN2B1 ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Mannosidase Alpha Class 2B Member 1 (MAN2B1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Mannosidase Alpha Class 2B Member 1 (MAN2B1) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Mannosidase alpha class 2B member 1
Gene Aliases
LAMAN; lysosomal acid alpha-mannosidase; lysosomal alpha-mannosidase; MANB; Mannosidase alpha class 2B member 1; mannosidase alpha-B; mannosidase, alpha B, lysosomal.
Gene ID
4125
Accession Number
NP_000519
Reactivity
Homo sapiens|Human
Target
Necessary for the catabolism of N-linked carbohydrates released during glycoprotein turnover. Cleaves all known types of alpha-mannosidic linkages.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mannosidase Alpha Class 2B Member 1 (MAN2B1) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mannosidase Alpha Class 2B Member 1 (MAN2B1) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mannosidase Alpha Class 2B Member 1 (MAN2B1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Mannosidase Alpha Class 2B Member 1 (MAN2B1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Detection Range
31.25-2000pg/mL
Recovery
Matrix Recovery Range (%) Average (%) serum (n=5) 90-102 99 EDTA plasma (n=5) 78-102 88 heparin plasma (n=5) 88-95 91 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) serum (n=5) 90-102 99 serum (n=5) 90-102 99 EDTA plasma (n=5) 78-102 88 EDTA plasma (n=5) 78-102 88 heparin plasma (n=5) 88-95 91 heparin plasma (n=5) 88-95 91
Sensitivity
< 14.7 pg/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-MAN2B1 Microplate 96 Wells (12 x 8 Well Strips) MAN2B1 Lyophilized Standard 2 x 2 ng 100X Biotinylated MAN2B1 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-MAN2B1 Microplate 96 Wells (12 x 8 Well Strips) Anti-MAN2B1 Microplate 96 Wells (12 x 8 Well Strips) MAN2B1 Lyophilized Standard 2 x 2 ng MAN2B1 Lyophilized Standard 2 x 2 ng 100X Biotinylated MAN2B1 Detector Antibody 120 uL 100X Biotinylated MAN2B1 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Notes
Formerly GWB-KBBPH4
Specificity
This assay has high sensitivity and excellent specificity for detection of Mannosidase Alpha Class 2B Member 1 (MAN2B1) . No significant cross-reactivity or interference between Mannosidase Alpha Class 2B Member 1 (MAN2B1) and analogues was observed.
Protein Length
1011
NCBI Gene Symbol
MAN2B1
Protein Name
Lysosomal alpha-mannosidase
Gene Name URL
MAN2B1
Nucleotide Accession Number
NM_000528.3
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items