Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

MYH7B ELISA Kit (Human)

Product Specifications

Reproducibility

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%

CAS Number

7732-18-5

Gene Name

Myosin heavy chain 7B

Gene Aliases

Antigen MLAA-21; MHC14; MYH14; Myosin cardiac muscle beta chain; Myosin heavy chain 7B, cardiac muscle beta isoform; myosin, heavy chain 7B, cardiac muscle, beta; myosin, heavy polypeptide 7B, cardiac muscle, beta; myosin-7B; slow A MYH14; U937-associated antigen.

Gene ID

57644

Accession Number

NP_065935

Reactivity

Homo sapiens|Human

Target

Involved in muscle contraction.

Type

ELISA Kit

Applications

Enzyme-linked Immunosorbent assay-Sandwich

Detection Method

Colorimetric

Assay Principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Assay Protocol

Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Antibody Array (AA) Protocol

Sample Type

Serum, plasma, tissue homogenates and other biological fluids.

Detection Range

0.156-10ng/mL

Recovery

Matrix Recovery Range (%) Average (%) serum (n=5) 78-92 83 EDTA plasma (n=5) 79-104 82 heparin plasma (n=5) 82-89 86 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) serum (n=5) 78-92 83 serum (n=5) 78-92 83 EDTA plasma (n=5) 79-104 82 EDTA plasma (n=5) 79-104 82 heparin plasma (n=5) 82-89 86 heparin plasma (n=5) 82-89 86

Sensitivity

< 0.069 ng/mL

Reconstitution

2°C to 8°C|-20°C

Components

Component Amount Anti-MYH7B Microplate 96 Wells (12 x 8 Well Strips) MYH7B Lyophilized Standard 2 x 10 ng 100X Biotinylated MYH7B Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-MYH7B Microplate 96 Wells (12 x 8 Well Strips) Anti-MYH7B Microplate 96 Wells (12 x 8 Well Strips) MYH7B Lyophilized Standard 2 x 10 ng MYH7B Lyophilized Standard 2 x 10 ng 100X Biotinylated MYH7B Detector Antibody 120 uL 100X Biotinylated MYH7B Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL

Notes

Formerly GWB-KBBWB5

Specificity

This assay has high sensitivity and excellent specificity for detection of Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) . No significant cross-reactivity or interference between Myosin Heavy Chain 7B, Cardiac Muscle Beta (MYH7B) and analogues was observed.

Protein Length

1941

NCBI Gene Symbol

MYH7B

Protein Name

Myosin-7B

Gene Name URL

MYH7B

Nucleotide Accession Number

NM_020884.4

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Zygote Arrest 1 (ZAR1) Antibody (FITC)
abx333614-01 20 µg

Zygote Arrest 1 (ZAR1) Antibody (FITC)

Ask
View Details
Zygote Arrest 1 (ZAR1) Antibody (FITC)
abx333614-02 50 µg

Zygote Arrest 1 (ZAR1) Antibody (FITC)

Ask
View Details
Zygote Arrest 1 (ZAR1) Antibody (FITC)
abx333614-03 100 µg

Zygote Arrest 1 (ZAR1) Antibody (FITC)

Ask
View Details
Zygote Arrest 1 (ZAR1) Antibody (FITC)
abx333614-04 200 µg

Zygote Arrest 1 (ZAR1) Antibody (FITC)

Ask
View Details
Zygote Arrest 1 (ZAR1) Antibody (FITC)
abx333614-05 1 mg

Zygote Arrest 1 (ZAR1) Antibody (FITC)

Ask
View Details
CRP3 (A-5) Alexa Fluor® 594
sc-166930 AF594 200 µg/mL

CRP3 (A-5) Alexa Fluor® 594

Ask
View Details