PDCD1LG2 ELISA Kit (Human)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Programmed Cell Death Protein 1 Ligand 2 (PDL2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Programmed Cell Death Protein 1 Ligand 2 (PDL2) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Programmed cell death 1 ligand 2
Gene Aliases
B7 dendritic cell molecule; B7DC; B7-DC; bA574F11.2; Btdc; butyrophilin B7-DC; CD273; PD-1-ligand 2; PDCD1 ligand 2; PDCD1L2; PDL2; PD-L2; programmed cell death 1 ligand 2; programmed death ligand 2.
Gene ID
80380
Accession Number
NP_079515
Reactivity
Homo sapiens|Human
Target
Involved in the costimulatory signal, essential for T-cell proliferation and IFNG production in a PDCD1-independent manner. Interaction with PDCD1 inhibits T-cell proliferation by blocking cell cycle progression and cytokine production (By similarity) .
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Programmed Cell Death Protein 1 Ligand 2 (PDL2) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Programmed Cell Death Protein 1 Ligand 2 (PDL2) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Programmed Cell Death Protein 1 Ligand 2 (PDL2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Programmed Cell Death Protein 1 Ligand 2 (PDL2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Detection Range
0.156-10ng/mL
Recovery
Matrix Recovery Range (%) Average (%) serum (n=5) 84-98 95 EDTA plasma (n=5) 78-96 84 heparin plasma (n=5) 83-97 90 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) serum (n=5) 84-98 95 serum (n=5) 84-98 95 EDTA plasma (n=5) 78-96 84 EDTA plasma (n=5) 78-96 84 heparin plasma (n=5) 83-97 90 heparin plasma (n=5) 83-97 90
Sensitivity
< 0.056 ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-PDCD1LG2 Microplate 96 Wells (12 x 8 Well Strips) PDCD1LG2 Lyophilized Standard 2 x 10 ng 100X Biotinylated PDCD1LG2 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-PDCD1LG2 Microplate 96 Wells (12 x 8 Well Strips) Anti-PDCD1LG2 Microplate 96 Wells (12 x 8 Well Strips) PDCD1LG2 Lyophilized Standard 2 x 10 ng PDCD1LG2 Lyophilized Standard 2 x 10 ng 100X Biotinylated PDCD1LG2 Detector Antibody 120 uL 100X Biotinylated PDCD1LG2 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Notes
Formerly GWB-KBBKA1
Specificity
This assay has high sensitivity and excellent specificity for detection of Programmed Cell Death Protein 1 Ligand 2 (PDCD1LG2) . No significant cross-reactivity or interference between Programmed Cell Death Protein 1 Ligand 2 (PDCD1LG2) and analogues was observed.
Protein Length
273
NCBI Gene Symbol
PDCD1LG2
Protein Name
Programmed cell death 1 ligand 2
Gene Name URL
PDCD1LG2
Nucleotide Accession Number
NM_025239.3
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items