STAT6 ELISA Kit (Rat)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 6 (STAT6) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 6 (STAT6) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Signal transducer and activator of transcription 6
Gene Aliases
Signal transducer and activator of transcription 6; signal transducer and activator of transcription 6, interleukin-4 induced; signal transducer and transcription activator 6.
Gene ID
362896
Accession Number
NP_001037715
Reactivity
Rat|Rattus norvegicus
Target
Signal transducer and activator of transcription
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Signal Transducer And Activator Of Transcription 6 (STAT6) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Signal Transducer And Activator Of Transcription 6 (STAT6) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Signal Transducer And Activator Of Transcription 6 (STAT6), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Signal Transducer And Activator Of Transcription 6 (STAT6) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Detection Range
0.312-20ng/mL
Recovery
Matrix Recovery Range (%) Average (%) serum (n=5) 97-105 102 EDTA plasma (n=5) 95-105 101 heparin plasma (n=5) 89-103 93 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) serum (n=5) 97-105 102 serum (n=5) 97-105 102 EDTA plasma (n=5) 95-105 101 EDTA plasma (n=5) 95-105 101 heparin plasma (n=5) 89-103 93 heparin plasma (n=5) 89-103 93
Sensitivity
< 5.8 pg/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-Stat6 Microplate 96 Wells (12 x 8 Well Strips) Stat6 Lyophilized Standard 2 x 1 ng 100X Biotinylated Stat6 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-Stat6 Microplate 96 Wells (12 x 8 Well Strips) Anti-Stat6 Microplate 96 Wells (12 x 8 Well Strips) Stat6 Lyophilized Standard 2 x 1 ng Stat6 Lyophilized Standard 2 x 1 ng 100X Biotinylated Stat6 Detector Antibody 120 uL 100X Biotinylated Stat6 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Notes
Formerly GWB-KBBVG3
Specificity
This assay has high sensitivity and excellent specificity for detection of Signal Transducer And Activator Of Transcription 6 (STAT6) . No significant cross-reactivity or interference between Signal Transducer And Activator Of Transcription 6 (STAT6) and analogues was observed.
Protein Length
841
NCBI Gene Symbol
Stat6
Protein Name
Signal transducer and activator of transcription
Gene Name URL
Stat6
Nucleotide Accession Number
NM_001044250.1
Curated Selection
Explore Other Products