CCL2 ELISA Kit (Rabbit)
Product Specifications
Reproducibility
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Monocyte Chemotactic Protein 1 (MCP1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Monocyte Chemotactic Protein 1 (MCP1) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
CAS Number
7732-18-5
Gene Name
Chemokine (C-C motif) ligand 2
Gene Aliases
C-C motif chemokine 2; MCP-1; Monocyte chemoattractant protein 1; monocyte chemoattractant protein-1; monocyte chemotactic protein 1; small-inducible cytokine A2.
Gene ID
100009130
Accession Number
NP_001075763
Reactivity
Oryctolagus cuniculus|Rabbit
Target
Chemotactic factor that attracts monocytes, but not neutrophils.
Type
ELISA Kit
Applications
Enzyme-linked Immunosorbent assay-Sandwich
Detection Method
Colorimetric
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Monocyte Chemotactic Protein 1 (MCP1) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Monocyte Chemotactic Protein 1 (MCP1) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Monocyte Chemotactic Protein 1 (MCP1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Monocyte Chemotactic Protein 1 (MCP1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
15.6-1,000pg/mL
Recovery
Matrix Recovery Range (%) Average (%) serum (n=5) 85-101 90 EDTA plasma (n=5) 84-91 88 heparin plasma (n=5) 91-98 94 Matrix Recovery Range (%) Average (%) Matrix Recovery Range (%) Average (%) serum (n=5) 85-101 90 serum (n=5) 85-101 90 EDTA plasma (n=5) 84-91 88 EDTA plasma (n=5) 84-91 88 heparin plasma (n=5) 91-98 94 heparin plasma (n=5) 91-98 94
Sensitivity
< 0.121 ng/mL
Reconstitution
2°C to 8°C|-20°C
Components
Component Amount Anti-CCL2 Microplate 96 Wells (12 x 8 Well Strips) CCL2 Lyophilized Standard 2 x 1 ng 100X Biotinylated CCL2 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Component Amount Component Amount Anti-CCL2 Microplate 96 Wells (12 x 8 Well Strips) Anti-CCL2 Microplate 96 Wells (12 x 8 Well Strips) CCL2 Lyophilized Standard 2 x 1 ng CCL2 Lyophilized Standard 2 x 1 ng 100X Biotinylated CCL2 Detector Antibody 120 uL 100X Biotinylated CCL2 Detector Antibody 120 uL Avidin/HRP Conjugate 120 uL Avidin/HRP Conjugate 120 uL Standard Diluent 1 x 20 mL Standard Diluent 1 x 20 mL Detector Antibody Diluent 1 x 12 mL Detector Antibody Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL Conjugate Diluent 1 x 12 mL 30X Wash Buffer 1 x 20 mL 30X Wash Buffer 1 x 20 mL TMB Substrate 1 x 9 mL TMB Substrate 1 x 9 mL Stop Solution 1 x 6 mL Stop Solution 1 x 6 mL
Notes
Formerly GWB-KBBXV6
Specificity
This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 1 (MCP1) . No significant cross-reactivity or interference between Monocyte Chemotactic Protein 1 (MCP1) and analogues was observed.
Protein Length
125
NCBI Gene Symbol
CCL2
Protein Name
C-C motif chemokine 2
Gene Name URL
CCL2
Nucleotide Accession Number
NM_001082294.1
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items