Epiandrosterone ELISA Kit
Product Specifications
Reproducibility
Sample Epiandrosterone Conc. (ng/mL) %CV 1 13.84 6.4 2 7.81 9.5 3 5.45 7.9 4 2.45 9.6 5 2.08 8.1 Sample Epiandrosterone Conc. (ng/mL) %CV Sample Epiandrosterone Conc. (ng/mL) %CV 1 13.84 6.4 1 13.84 6.4 2 7.81 9.5 2 7.81 9.5 3 5.45 7.9 3 5.45 7.9 4 2.45 9.6 4 2.45 9.6 5 2.08 8.1 5 2.08 8.1 Sample Epiandrosterone Conc. (ng/mL) %CV 1 13.84 10.1 2 8.17 16.2 3 5.34 14.8 4 2.25 18.8 5 1.97 19.8 Sample Epiandrosterone Conc. (ng/mL) %CV Sample Epiandrosterone Conc. (ng/mL) %CV 1 13.84 10.1 1 13.84 10.1 2 8.17 16.2 2 8.17 16.2 3 5.34 14.8 3 5.34 14.8 4 2.25 18.8 4 2.25 18.8 5 1.97 19.8 5 1.97 19.8
Gene Name
Epiandrosterone
Type
ELISA Kit
Applications
Enzyme-linked immunosorbent assay
Assay Principle
The DetectX® Epiandrosterone Immunoassay kit uses a specifically generated antibody to measure Epiandrosterone in urine, saliva, and fecal samples, or in extracted serum and plasma. This kit is not recommended for serum or plasma samples without extraction. The kit will also quantitatively measure epiandrosterone present in reconstituted buffer samples and tissue culture media samples. Please read the complete kit insert before performing this assay. An epiandrosterone standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or diluted samples are pipetted into a clear microtiter plate coated with an antibody to capture rabbit antibodies. An Epiandrosterone-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a polyclonal antibody to epiandrosterone to each well. After a two hour incubation the plate is washed and substrate added. The substrate reacts with the bound epiandrosterone-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450 nm wavelength. The concentration of the epiandrosterone in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers.
Assay Protocol
Reconstitution & Storage Instructions Western Blotting/Immunoblotting (WB/IB) Protocol Immunohistochemistry (IHC) Protocol Immunocytochemistry (ICC) Protocol Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol Blocking Peptide Competition Protocol (BPCP) Immunoprecipitation (IP) Protocol Antibody Array (AA) Protocol Reconstitution & Storage Instructions
Reconstitution & Storage Instructions
Western Blotting/Immunoblotting (WB/IB) Protocol
Western Blotting/Immunoblotting (WB/IB) Protocol
Immunohistochemistry (IHC) Protocol
Immunohistochemistry (IHC) Protocol
Immunocytochemistry (ICC) Protocol
Immunocytochemistry (ICC) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Enzyme-Linked ImmunoSorbent Assay (ELISA) Protocol
Blocking Peptide Competition Protocol (BPCP)
Blocking Peptide Competition Protocol (BPCP)
Immunoprecipitation (IP) Protocol
Immunoprecipitation (IP) Protocol
Antibody Array (AA) Protocol
Antibody Array (AA) Protocol
Sample Type
Dried Fecal Extracts, Saliva, Urine, Extracted Serum/Plasma, and Tissue Culture Media
Sensitivity
0.120 ng/mL
Reconstitution
2°C to 8°C
Components
Component Quantity Coated Clear 96 Well Plate 1 or 5 Each Epiandrosterone Standard 125 uL or 625 uL DetectX® Epiandrosterone Antibody 3 mL or 13 mL DetectX® Epiandrosterone Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Component Quantity Component Quantity Coated Clear 96 Well Plate 1 or 5 Each Coated Clear 96 Well Plate 1 or 5 Each Epiandrosterone Standard 125 uL or 625 uL Epiandrosterone Standard 125 uL or 625 uL DetectX® Epiandrosterone Antibody 3 mL or 13 mL DetectX® Epiandrosterone Antibody 3 mL or 13 mL DetectX® Epiandrosterone Conjugate 3 mL or 13 mL DetectX® Epiandrosterone Conjugate 3 mL or 13 mL Assay Buffer Concentrate 28 mL or 55 mL Assay Buffer Concentrate 28 mL or 55 mL Wash Buffer Concentrate 30 mL or 125 mL Wash Buffer Concentrate 30 mL or 125 mL TMB Substrate 11 mL or 55 mL TMB Substrate 11 mL or 55 mL Stop Solution 5 mL or 25 mL Stop Solution 5 mL or 25 mL Plate Sealer 1 or 5 Each Plate Sealer 1 or 5 Each
CAS Number
7732-18-5