ELISA Kit for Lymphoid Enhancer Binding Factor 1 (LEF1)
Product Specifications
Product Name Alternative
TCF1ALPHA; T cell-specific transcription factor 1-alpha
UniProt
Q9UJU2
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Field of Research
Tumor immunity
Assay Principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Lymphoid Enhancer Binding Factor 1 (LEF1) . Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Lymphoid Enhancer Binding Factor 1 (LEF1) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Lymphoid Enhancer Binding Factor 1 (LEF1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Lymphoid Enhancer Binding Factor 1 (LEF1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay Performance Time
3h
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Detection Range
0.156-10ng/mL
Precision
Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Lymphoid Enhancer Binding Factor 1 (LEF1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Lymphoid Enhancer Binding Factor 1 (LEF1) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV
Sensitivity
The minimum detectable dose of this kit is typically less than 0.062ng/mL
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Format
48T, 96T, 96Tx5, 96Tx10, 96Tx100
Specificity
This assay has high sensitivity and excellent specificity for detection of Lymphoid Enhancer Binding Factor 1 (LEF1) . No significant cross-reactivity or interference between Lymphoid Enhancer Binding Factor 1 (LEF1) and analogues was observed.
Product Name Synonym
Lymphoid Enhancer Binding Factor 1
Method
Double-antibody Sandwich
Organism Species
Homo sapiens (Human)
Available Sizes
Curated Selection