Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Multiplex Assay Kit for Grancalcin (GCA)

Product Specifications

UniProt

P28676

Applications

FLIA Kit for Antigen Detection.

Assay Principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

Assay Protocol

1. Preparation of standards, reagents and samples before the experiment; <br/> 2. Add 100μL standard or sample to each well, <br/> &nbsp; &nbsp; &nbsp; &nbsp; add 10μL magnetic beads, and incubate 90min at 37&deg; C on shaker; <br/> 3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37&deg; C on shaker; <br/> 4. Wash plate on magnetic frame for three times; <br/> 5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37&deg; C on shaker; <br/> 6. Wash plate on magnetic frame for three times; <br/> 7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.<br/>

Assay Performance Time

3H

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Detection Range

0.01 - 10 ng/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level of the target, etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100, Intra-Assay: CV<10%, Inter-Assay: CV<12%

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003ng/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Specificity

This assay has high sensitivity and excellent specificity for detection of the target, etc. by FLIA (Flow Luminescence Immunoassay) .<br/> No significant cross-reactivity or interference between the target, etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Method

Double-Antibody Sandwich

Organism Species

Homo sapiens (Human)

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Tissue FFPE Sections, Prostate
CS804076 5x 5 µm

Tissue FFPE Sections, Prostate

Ask
View Details
RBMXL2 CRISPR All-in-one AAV vector set (with saCas9)(Mouse)
38664154 3x1.0μg DNA

RBMXL2 CRISPR All-in-one AAV vector set (with saCas9)(Mouse)

Ask
View Details
SYTL3 (NM_001009991) Human Tagged Lenti ORF Clone
RC212752L3 10 µg

SYTL3 (NM_001009991) Human Tagged Lenti ORF Clone

Ask
View Details
Human Common gamma Chain (NP_000197) VersaClone cDNA
RDC1129 10 µg

Human Common gamma Chain (NP_000197) VersaClone cDNA

Ask
View Details