Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

Multiplex Assay Kit for D-Dimer (D2D), etc. by FLIA (Flow Luminescence Immunoassay)

Product Specifications

Product Name Alternative

D 2 Dimer

Synonyms

D-Dimer

Applications

FLIA Kit for Antigen Detection.

Field of Research

Hematology, Cardiovascular biology

Assay Principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

Assay Protocol

1. Preparation of standards, reagents and samples before the experiment; <br/> 2. Add 50μL standard or sample to each well, <br/> &nbsp; &nbsp; &nbsp; &nbsp; add 10μL magnetic beads, and 50μL Detection Reagent A, incubate 90min at 37&deg; C on shaker; <br/> 3. Wash plate on magnetic frame for three times; <br/> 4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37&deg; C on shaker; <br/> 5. Wash plate on magnetic frame for three times; <br/> 6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.<br/>

Assay Performance Time

3H

Sample Type

Plasma

Detection Range

48.83 - 50000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level D-Dimer (D2D), etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level D-Dimer (D2D), etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 16.277 pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of D-Dimer (D2D), etc. by FLIA (Flow Luminescence Immunoassay) .<br/> No significant cross-reactivity or interference between D-Dimer (D2D), etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Homo sapiens (Human)

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

1-Deoxy-1-(octylamino)-D-glucitol
TRC-D245500-10G 10 g

1-Deoxy-1-(octylamino)-D-glucitol

Ask
View Details
Seh1 Lentiviral Activation Particles (m)
sc-428243-LAC 200 µL

Seh1 Lentiviral Activation Particles (m)

Ask
View Details
ROPN1L CRISPRa sgRNA lentivector (set of three targets)(Human)
40684121 3 x 1.0μg DNA

ROPN1L CRISPRa sgRNA lentivector (set of three targets)(Human)

Ask
View Details
HoxC6 (B-7) AC
sc-376330 AC 500 µg/mL, 25% ag

HoxC6 (B-7) AC

Ask
View Details
NODAGA-NHS
HY-156991 Inquire

NODAGA-NHS

Ask
View Details