Multiplex Assay Kit for Gamma-Endorphin (gEP), etc. by FLIA (Flow Luminescence Immunoassay)

Product Specifications

Synonyms

Gamma-Endorphin

UniProt

P01193

Applications

FLIA Kit for Antigen Detection.

Assay Principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

Assay Protocol

1. Preparation of standards, reagents and samples before the experiment; <br/> 2. Add 50μL standard or sample to each well, <br/> &nbsp; &nbsp; &nbsp; &nbsp; add 10μL magnetic beads, and 50μL Detection Reagent A, incubate 90min at 37&deg; C on shaker; <br/> 3. Wash plate on magnetic frame for three times; <br/> 4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37&deg; C on shaker; <br/> 5. Wash plate on magnetic frame for three times; <br/> 6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.<br/>

Assay Performance Time

3H

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.

Detection Range

0.98 - 1000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Gamma-Endorphin (gEP), etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Gamma-Endorphin (gEP), etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Gamma-Endorphin (gEP), etc. by FLIA (Flow Luminescence Immunoassay) .<br/> No significant cross-reactivity or interference between Gamma-Endorphin (gEP), etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Mus musculus (Mouse)

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

UQCRC2 Recombinant Protein Antigen
NBP1-80862PEP 0.1 mL

UQCRC2 Recombinant Protein Antigen

Ask
View Details
Anti-Hu CD64 Purified
MBS1800003-01 0.1 mg

Anti-Hu CD64 Purified

Ask
View Details
Anti-Hu CD64 Purified
MBS1800003-02 5x 0.1 mg

Anti-Hu CD64 Purified

Ask
View Details
Rabbit Polyclonal CGREF1 Antibody [DyLight 680]
NBP2-99923FR 0.1 mL

Rabbit Polyclonal CGREF1 Antibody [DyLight 680]

Ask
View Details
Plozalizumab
E40YR1384 1 mg

Plozalizumab

Ask
View Details