Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Aldosterone (ALD)

Product Specifications

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Aldosterone (ALD) . A competitive inhibition reaction is launched between biotin labeled Aldosterone (ALD) and unlabeled Aldosterone (ALD) (Standards or samples) with the pre-coated antibody specific to Aldosterone (ALD) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Aldosterone (ALD) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Aldosterone (ALD) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well.<br/> &nbsp; &nbsp; &nbsp; &nbsp; And then add 50&micro; L prepared Detection Reagent A immediately. <br/> &nbsp; &nbsp; &nbsp; &nbsp; Shake and mix. Incubate 1 hour at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 7. Read RLU value immediately.<br/>

Assay Performance Time

2H

Sample Type

Serum, plasma and other biological fluids

Detection Range

7.81 - 2000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Aldosterone (ALD) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Aldosterone (ALD) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 2.93pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Aldosterone (ALD) .<br/> No significant cross-reactivity or interference between Aldosterone (ALD) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Pan-species (General)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Recombinant Human ZW10
P9234-01 50 µg

Recombinant Human ZW10

Ask
View Details
Recombinant Human ZW10
P9234-02 200 µg

Recombinant Human ZW10

Ask
View Details
Recombinant Human ZW10
P9234-03 1 mg

Recombinant Human ZW10

Ask
View Details
Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody
MBS1756808-01 0.03 mL

Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody

Ask
View Details
Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody
MBS1756808-02 0.1 mL

Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody

Ask
View Details
Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody
MBS1756808-03 5x 0.1 mL

Anti-NFIB/NF1B2 Rabbit Monoclonal Antibody

Ask
View Details