Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Complement Component 4d (C4d)

Product Specifications

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Complement Component 4d (C4d) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Complement Component 4d (C4d) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Complement Component 4d (C4d) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma and other biological fluids

Detection Range

1.37 - 1000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Complement Component 4d (C4d) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Complement Component 4d (C4d) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.61pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Complement Component 4d (C4d) .<br/> No significant cross-reactivity or interference between Complement Component 4d (C4d) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Anti-human Granzyme B mAb (MT28), biotin
3486-4-250 250 µg

Anti-human Granzyme B mAb (MT28), biotin

Ask
View Details
Apollon Lentiviral Activation Particles (h2)
sc-405428-LAC-2 200 µL

Apollon Lentiviral Activation Particles (h2)

Ask
View Details
B33-125-2-7642 AF Systems Consumables
142898 Box of 500 Piece(s)

B33-125-2-7642 AF Systems Consumables

Ask
View Details
smad7 CRISPR All-in-one AAV vector set (with saCas9)(Human)
44399151 3x1.0μg DNA

smad7 CRISPR All-in-one AAV vector set (with saCas9)(Human)

Ask
View Details
SLC27A4 Polyclonal Antibody
MBS8573454-01 0.1 mL

SLC27A4 Polyclonal Antibody

Ask
View Details
SLC27A4 Polyclonal Antibody
MBS8573454-02 0.1 mL (AF405L)

SLC27A4 Polyclonal Antibody

Ask
View Details